I have used a PMC board by general standards. 64 parallel channels
(i.e., no mux).
www.generalstandards.com
- Till
On 10/14/2015 05:30 PM, Michael Davidsaver wrote:
All,
I've been asked for advise on finding a digitizer for a fast thermometry
application (RTDs). The desire is for a sampling range in the range of
50-100 KSPS with 16-bit resolution over +-10 V. There will be ~200
channels in total, so I think a high density solution would be
appropriate. Pre-existing epics support is of course a plus.
The first solution to come to my mind is industry pack. Something like
the hytec IP-VAD-8418.
What options are available for this "middle" speed range?
Thanks,
Michael
- Replies:
- RE: mid-speed digitizer options? Mazanec Tomáš
- References:
- mid-speed digitizer options? Michael Davidsaver
- Navigate by Date:
- Prev:
RE: mid-speed digitizer options? Mark Rivers
- Next:
Modbus Binary Output Readbacks Wallace, Alex
- Index: