1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  <20162017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  <20162017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: Micronix MMC-200 motor controller
From: Kevin Peterson <[email protected]>
To: 김지화(빔라인장치팀) <[email protected]>, "[email protected]" <[email protected]>
Date: Fri, 13 May 2016 09:02:59 -0500
The controller is used by a couple beamlines at Argonne's Advance Photon
Source.

A example config is included in the motor module:

https://github.com/epics-modules/motor/blob/master/iocBoot/iocWithAsyn/motor.cmd.mmc200

The EPICS motor driver for the MMC-200 also supports the MMC-100.

Kevin

References:
Micronix MMC-200 motor controller 김지화(빔라인장치팀)

Navigate by Date:
Prev: Re: Question about Archive Engine Kasemir, Kay
Next: Re: EPICS support with NI-Daqmx Ana Malagon
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  <20162017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Micronix MMC-200 motor controller 김지화(빔라인장치팀)
Next: testAsynPortDriver questions Silver
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  <20162017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 15 Jul 2016 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·