1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
<== Date ==> <== Thread ==>

Subject: RE: RETIGA?
From: "Pearson, Matthew R. via Tech-talk" <tech-talk at aps.anl.gov>
To: John Dobbins <john.dobbins at cornell.edu>
Cc: "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov>
Date: Tue, 5 Jan 2021 16:24:27 +0000

Hi John,

 

The areaDetector website has a list of cameras, some of which are cooled. I haven’t used QImaging cameras, but I can recommend Andor CCDs (USB2 based). On one of our beamlines we have had an Andor iKon CCD being used as the main detector for about 8 years. The latest versions of those cameras can be cooled down to -100C. These are not high frame rate cameras, and are optimized for low noise and astronomy (low light, long exposure) applications.

 

A more affordable option might be a camera from SBIG, which have several cooled options.

 

If you’re more interested in frame rates, a sCMOS camera might be best. These will have the higher speed readout options like USB3.

 

Cheers,

Matt

 

 

From: Tech-talk <tech-talk-bounces at aps.anl.gov> On Behalf Of John Dobbins via Tech-talk
Sent: Monday, January 4, 2021 4:41 PM
To: EPICS tech-talk <tech-talk at aps.anl.gov>
Subject: [EXTERNAL] RETIGA?

 

Happy New Year!

 

We have an old QImaging RETIGA 4000DC camera. This is a Peltier cooled (down to -45 C) sensor with Firewire interface, ~ 4 Megapixel.

 

I am looking for a replacement.  There is a RETIGA LUMO which is similar but with a USB3 interface?  Does anyone know if the existing ADQimaging works with this camera/interface?

 

Does anyone want to recommend another cooled camera with existing EPICS support?


Thanks,

 

John Dobbins

 

Research Support Specialist

Cornell High Energy Synchrotron Source

Cornell University

 

 

 

 


Replies:
Re: RETIGA? Mark Rivers via Tech-talk
References:
RETIGA? John Dobbins via Tech-talk

Navigate by Date:
Prev: Re: EPICS for Building a SCADA System for Energy Grids; Interface to NI VeriStand Mark Rivers via Tech-talk
Next: Re: RETIGA? Mark Rivers via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
Navigate by Thread:
Prev: RETIGA? John Dobbins via Tech-talk
Next: Re: RETIGA? Mark Rivers via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
ANJ, 05 Jan 2021 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·