1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024  2025  2026  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024  2025  2026 
<== Date ==> <== Thread ==>

Subject: Re: Autosave PVs showing up as INVALID(UDF_ALARM)
From: "Mooney, Tim M. via Tech-talk" <[email protected]>
To: "[email protected]" <[email protected]>, Iain Marcuson <[email protected]>
Date: Wed, 3 Feb 2021 19:58:48 +0000
Hi Iain,

You could try writing to the PROC field to verify that processing the record clears the UDF field.  If it does, then you could set the TPRO field in the database, and reboot, to check that the fanout record is actually processing the record.

Tim Mooney ([email protected]) (630)252-5417
Beamline Controls Group (www.aps.anl.gov)
Advanced Photon Source, Argonne National Lab


From: Tech-talk <[email protected]> on behalf of Iain Marcuson via Tech-talk <[email protected]>
Sent: Wednesday, February 3, 2021 1:11 PM
To: [email protected] <[email protected]>
Subject: Autosave PVs showing up as INVALID(UDF_ALARM)
 

I am using autosave in an IOC.  Several PVs show up as INVALID(UDF_ALARM).  Autosave is set to restore in pass 1, and the PVs appear to be in the autosave .sav files.  In addition, I use a series of fanout records to try to force processing of the PVs, although I again get the Undefined status.  Are there any items I can check to try to resolve this?

 

Thank you,

 

Iain Marcuson

Software Engineer, Sydor Technologies

585.278.1168 | www.SydorTechnologies.com

Skype: [email protected]

 


Replies:
RE: Autosave PVs showing up as INVALID(UDF_ALARM) Iain Marcuson via Tech-talk
References:
Autosave PVs showing up as INVALID(UDF_ALARM) Iain Marcuson via Tech-talk

Navigate by Date:
Prev: RE: Re: Re: modbus write registers error to Pilz PLC Mark Rivers via Tech-talk
Next: RE: PerkinElmer Area Detector on Windows 10 [SEC=OFFICIAL] CORNALL, Terry via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024  2025  2026 
Navigate by Thread:
Prev: Autosave PVs showing up as INVALID(UDF_ALARM) Iain Marcuson via Tech-talk
Next: RE: Autosave PVs showing up as INVALID(UDF_ALARM) Iain Marcuson via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024  2025  2026 
ANJ, 19 Mar 2026 · Home · News · About · Talk · Base · Modules · Extensions ·
· Distributions · Download · Documents · Links · Licensing ·