1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: [EXTERNAL] Question about image widget in Phoebus
From: Florian Feldbauer via Tech-talk <tech-talk at aps.anl.gov>
To: "Kasemir, Kay" <kasemirk at ornl.gov>, Mark Rivers <rivers at cars.uchicago.edu>
Cc: "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov>
Date: Thu, 29 Apr 2021 17:52:52 +0200

Hey Kay,


yes I know, but the display didn't work for me, so I thought maybe I need the cursor PVs.
That's why I asked for their meaning in my first mail.
But looking at the example I found my mistake, why my waveform was not displayed correctly.


Cheers,
Florian


Am 29.04.2021 um 17:32 schrieb Kasemir, Kay:
from our pixel sensor we just get a list of pixels that have seen a hit (row and column address).

That's exactly what the SNS beamline detectors report.
They send messages which basically contain a time stamp, some detail about the beam pulse, and then a list of detector pixels which where hit and when exactly relative to the time stamp.

> We want to accumulate all hits and display them as 2d histogram (x-axis beeing column, y axis row and content of pixel = number of hits since start of the measurement).


Yes, we also need to to several things with that raw data.

It's streamed into files for later analysis, that's the basic data acquisition job.

It's put into X/Y histograms so you can display in near real time where the detector is hit, verify basic diffraction patterns.

It's put into time-of-flight histograms, into histograms that accumulate the energy or 'D-space' or ... of the hits.

But all that is done in IOCs, which then update an X/Y histogram image in basic area detector format, or waveforms for most of the rest. The display tool simply displays the image or waveform, it doesn't do any of the computations.


-Kay

-- 
Ruhr-Universität Bochum
AG der Experimentalphysik I
Dr. Florian Feldbauer
NB 2/131 / Fach 125
Universitätsstr. 150
D-44801 Bochum

Office: NB 2/134
Phone:  (+49)234 / 32-23563
Fax:    (+49)234 / 32-14170
https://paluma.ruhr-uni-bochum.de

References:
Question about image widget in Phoebus Florian Feldbauer via Tech-talk
Re: [EXTERNAL] Question about image widget in Phoebus Kasemir, Kay via Tech-talk
RE: [EXTERNAL] Question about image widget in Phoebus Mark Rivers via Tech-talk
Re: [EXTERNAL] Question about image widget in Phoebus Florian Feldbauer via Tech-talk
Re: [EXTERNAL] Question about image widget in Phoebus Kasemir, Kay via Tech-talk

Navigate by Date:
Prev: Re: [EXTERNAL] Question about image widget in Phoebus Kasemir, Kay via Tech-talk
Next: Re: how to install alh on raspberry pi 4 Huyn Woo Ryu via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
Navigate by Thread:
Prev: Re: [EXTERNAL] Question about image widget in Phoebus Kasemir, Kay via Tech-talk
Next: ADVimba disconnect John Dobbins via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
ANJ, 30 Apr 2021 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·