1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
<== Date ==> <== Thread ==>

Subject: JAI problem using ADAravis
From: Steve Kinder - STFC UKRI via Tech-talk <tech-talk at aps.anl.gov>
To: tech-talk <tech-talk at aps.anl.gov>
Date: Wed, 13 Oct 2021 16:27:58 +0000
I have a problem with JAI cameras attached to an IOC using ADGenICam/ADAravis to interface them. The IOC has 2 JAI BM-141GE cameras, one AVT G-235B and one AVT G-319B. Neither of the AVT cameras display any problem I have seen. However, on their first acquisition waveforms returned by the JAI cameras have sets of 32 zeros at what look like regular intervals throughout. Based on how the image looks when displayed I would say these are extra zeros rather than real data replaced with zeros. Once I stop and restart the cameras things then work as expected and the zeros are gone.

I have just downloaded and built what I believe are the lastest aravis/ADGenICam/ADAravis as below, built against these and the problem persists:

aravis : 0.8.18
ADGenICam : R1-8
ADAravis : R2-2-1

Any help and/or suggestions would be much appreciated.

Steve

This email and any attachments are intended solely for the use of the named recipients. If you are not the intended recipient you must not use, disclose, copy or distribute this email or any of its attachments and should notify the sender immediately and delete this email from your system. UK Research and Innovation (UKRI) has taken every reasonable precaution to minimise risk of this email or any attachments containing viruses or malware but the recipient should carry out its own virus and malware checks before opening the attachments. UKRI does not accept any liability for any losses or damages which the recipient may sustain due to presence of any viruses. 


Navigate by Date:
Prev: Re: Epics Archiver Appliance Storage Question Wilson, Andy (DLSLtd, RAL, LSCI) via Tech-talk
Next: Periodically calling shell functions in an IOC Wang, Andrew via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
Navigate by Thread:
Prev: phoebus-olog Leblanc, Gregory via Tech-talk
Next: Periodically calling shell functions in an IOC Wang, Andrew via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
ANJ, 13 Oct 2021 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·