1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  <20222023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  <20222023  2024 
<== Date ==> <== Thread ==>

Subject: Pheobus Alarm-System - Handling varying locations for associated displays
From: "Gotz, Malte via Tech-talk" <tech-talk at aps.anl.gov>
To: "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov>
Date: Tue, 15 Feb 2022 13:24:46 +0000

Hello everybody,

 

I am somewhat stuck trying to find a way to open displays from the alarm context menu in Phoebus on systems where these displays are in different absolute locations.

We are moving from EDM/MEDM and Alarmhandler to Phoebus. Where EDM and MEDM have a display search path, Phoebus requires relative or absolute paths. For related displays, we solved this transition by placing all displays in a single directory tree. Yet, the root of this tree may be at a different point on the file system or sometimes even on a webserver, which is not accessible from everywhere, though.

Now, to add a display to an alarm-node in Phoebus and pass macros to it, you must have a URI with an absolute path. Also, there is no macro substitution or variable expansion happening for these resource strings. I can’t see a way to make this accessible for systems with the displays in different locations.

So, how do others handle this? Do you have the displays in the same location on every system that needs to open them?

Instead of the display we could use a command and have a script resolve the path and then open Phoebus with that, but that feels like a crutch.

I appreciate any tips.

Best regards,

Malte

 

--------------

Malte Gotz

Accelerator Operation  - Control System Group

(BE-IA-AOT/ACS)

BESSYII and MLS @ Helmholtz-Zentrum Berlin




Helmholtz-Zentrum Berlin für Materialien und Energie GmbH

Mitglied der Hermann von Helmholtz-Gemeinschaft Deutscher Forschungszentren e.V.

Aufsichtsrat: Vorsitzender Dr. Volkmar Dietz, stv. Vorsitzende Dr. Jutta Koch-Unterseher
Geschäftsführung: Prof. Dr. Bernd Rech, Thomas Frederking

Sitz Berlin, AG Charlottenburg, 89 HRB 5583

Postadresse:
Hahn-Meitner-Platz 1
14109 Berlin
Deutschland

Replies:
Re: [EXTERNAL] Pheobus Alarm-System - Handling varying locations for associated displays Kasemir, Kay via Tech-talk

Navigate by Date:
Prev: Re: Alarm severity in PVA Michael Davidsaver via Tech-talk
Next: Re: [EXTERNAL] Pheobus Alarm-System - Handling varying locations for associated displays Kasemir, Kay via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  <20222023  2024 
Navigate by Thread:
Prev: Re: Alarm severity in PVA Michael Davidsaver via Tech-talk
Next: Re: [EXTERNAL] Pheobus Alarm-System - Handling varying locations for associated displays Kasemir, Kay via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  <20222023  2024 
ANJ, 14 Sep 2022 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·