EPICS Controls Argonne National Laboratory

Experimental Physics and
Industrial Control System

1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  <20232024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  <20232024 
<== Date ==> <== Thread ==>

Subject: how to use the GUN-RC-300 in mrfioc2
From: 문건영(선형가속기팀) via Tech-talk <tech-talk at aps.anl.gov>
To: "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov>
Date: Mon, 5 Jun 2023 07:55:01 +0000
Dear All,

I'm trying to operate the GUN-RC-300 on MTCA-EVR-300RF.
I made the mtca-evr-300rf.substitutions file as below by referring to file evr-tg-300.substitutions.
Fill in only the information related to gun-rc-300.
...
file "mrmevrout.db"
{pattern
{ON, OBJ, DESC}
{"$(SYS){$(D)-Out:Int}", "$(EVR):Int", "Internal"}
{"$(SYS){$(D)-Out:FP0}", "$(EVR):FrontOut0", "OUT0 (GTX)"}
{"$(SYS){$(D)-Out:FP1}", "$(EVR):FrontOut1", "OUT1 (GTX)"}
{"$(SYS){$(D)-Out:FP2}", "$(EVR):FrontOut2", "OUT2 (GTX)"}
{"$(SYS){$(D)-Out:FP3}", "$(EVR):FrontOut3", "OUT3 (GTX)"}

{"$(SYS){$(D)-Out:FPUV0}", "$(EVR):FrontUnivOut0", "FPUV0 (TTL)"}
{"$(SYS){$(D)-Out:FPUV1}", "$(EVR):FrontUnivOut1", "FPUV1 (TTL)"}
{"$(SYS){$(D)-Out:FPUV2}", "$(EVR):FrontUnivOut2", "FPUV2 (GTX)"}
{"$(SYS){$(D)-Out:FPUV3}", "$(EVR):FrontUnivOut3", "FPUV3 (GTX)"}
...
file "evrcml.db"
{pattern
{P, ON, OBJ}
{"$(SYS){$(D)}", "$(SYS){$(D)-Out:FP0}", "$(EVR):CML0"}
{"$(SYS){$(D)}", "$(SYS){$(D)-Out:FP1}", "$(EVR):CML1"}
{"$(SYS){$(D)}", "$(SYS){$(D)-Out:FP2}", "$(EVR):CML2"}
{"$(SYS){$(D)}", "$(SYS){$(D)-Out:FP3}", "$(EVR):CML3"}
{"$(SYS){$(D)}", "$(SYS){$(D)-Out:FPUV2}", "$(EVR):CML4"}
{"$(SYS){$(D)}", "$(SYS){$(D)-Out:FPUV3}", "$(EVR):CML5"}
}

file "evrcmlgun.db"
{pattern
{ON, OBJ}
{"$(SYS){$(D)-Out:FP0}", "$(EVR):CML0"}
{"$(SYS){$(D)-Out:FP1}", "$(EVR):CML1"}
{"$(SYS){$(D)-Out:FP2}", "$(EVR):CML2"}
{"$(SYS){$(D)-Out:FP3}", "$(EVR):CML3"}
...

When evr IOC is running, the "RX ON" indicator is ON in the GUN-RC-300.
But, "PULSE" indicator is not working. I don't know how to use it in CSS opi.
Or I'm not sure mtca-evr-300rf.substitutions file setting.

If anyone knows anything about this, I'd appreciate your help.

Best regards,
Geonyeong Mun
_________________________________________
Geonyeong Mun
Senior Engineer, Accelerator Division

Pohang Accelerator Laboratory (PAL) 
37673 80 Jigokro-127-beongil, Nam-gu, 
Pohang, Gyeongbuk, Korea

phone: +82 10 4164 - 2260
office: +82 54 279 - 1098
email: gymun at postech.ac.kr
web: pal.postech.ac.kr


Replies:
Re: how to use the GUN-RC-300 in mrfioc2 Michael Davidsaver via Tech-talk

Navigate by Date:
Prev: Re: Keysight oscilloscope DSOX1204a connection issue Eric Norum via Tech-talk
Next: Job Opportunity at BESSY II Smith, William via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  <20232024 
Navigate by Thread:
Prev: Re: Keysight oscilloscope DSOX1204a connection issue Eric Norum via Tech-talk
Next: Re: how to use the GUN-RC-300 in mrfioc2 Michael Davidsaver via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  <20232024 
ANJ, 12 Jun 2023 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·