1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  <20242025  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  <20242025 
<== Date ==> <== Thread ==>

Subject: Archiver Appliance missing aplliance.properties file
From: "Sintschuk, Michael via Tech-talk" <tech-talk at aps.anl.gov>
To: tech-talk <tech-talk at aps.anl.gov>
Date: Fri, 1 Nov 2024 10:38:43 +0000

Dear all,

 

I’m trying to install a recent EPICS Archiver Appliance (Version 2.0.5) using the install script like it is described in the docs:

https://epicsarchiver.readthedocs.io/en/latest/sysadmin/installguide.html#using-an-install-script

My system is an OpenSuSe – Leap 15.6 and the archiver installation should be the only one in the cluster / on the machine.

 

The install script, and the deployRelease.sh afterwards, both finish without errors.

However, when I start the archiver appliance via the sampleStartup.sh script, I get the following error in the log files of engine, etl, mgmt and retrieval:

 

2024-10-30 15:50:49,117 FATAL [main] config.DefaultConfigService (DefaultConfigService.java:293) - Exception loading the appliance properties file

 

 

I have an older archiver running version 1.1.0 on another machine. I also used the install script to install it. Looking into the folders:

 

…/engine/webapps/engine/WEB-INF/classes

…/etl/webapps/etl/WEB-INF/classes

…/mgmt/webapps/mgmt/WEB-INF/classes

…/retrieval/webapps/retrieval/WEB-INF/classes

 

I found the five files: appliances.xml; archappl.properties; failover_dest.xml; failover_other.xml and policies.py

By simply copying them into the same locations of my new archiver, it resolved the problem: the new archiver is starting.

 

I don’t remember making these files manually in the old installation.

Why are these files missing in the new installation? Did I forgot to set some settings before running the install script?

 

Best regards

Michael

 

Michael Sintschuk
Bundesanstalt für Materialforschung und –prüfung (BAM)
8.5 - X-ray Imaging

Unter den Eichen 87
12205 Berlin
GERMANY

P: +49 30 8062-15063 (BESSY, Adlershof)
michael.sintschuk at bam.de

 


Navigate by Date:
Prev: Re: pasynOctetSyncIO->read() weirdly slow performance Marco Filho via Tech-talk
Next: RE: Archiver Appliance missing aplliance.properties file Sky Brewer via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  <20242025 
Navigate by Thread:
Prev: Re: Procserv execute error Hu, Yong via Tech-talk
Next: RE: Archiver Appliance missing aplliance.properties file Sky Brewer via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  <20242025 
ANJ, 01 Nov 2024 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions ·
· Download · Search · IRMIS · Talk · Documents · Links · Licensing ·