1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  <20252026  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  <20252026 
<== Date ==> <== Thread ==>

Subject: RE: IOC PVs intermittently flicker between values and LINK INVALID
From: Mark Rivers via Tech-talk <[email protected]>
To: "Tran, Phi Dung" <[email protected]>, "[email protected]" <[email protected]>
Date: Thu, 21 Aug 2025 16:42:02 +0000

Have you run diagnostics like “top” to look at the CPU and memory usage of the IOC process, as well as the system as a whole?  It sounds like it could be a memory leak or CPU saturation issue?

 

Mark

 

 

From: Tech-talk <[email protected]> On Behalf Of Tran, Phi Dung via Tech-talk
Sent: Thursday, August 21, 2025 11:36 AM
To: [email protected]
Subject: IOC PVs intermittently flicker between values and LINK INVALID

 

Hello Tech-Talk,

I’m running into an issue where one of my IOCs behaves normally after a reboot, but after several days of uptime all PVs begin to flicker — they alternate between their correct values and LINK INVALID.

Some details:

  • Rebooting the IOC clears the issue temporarily, but the flickering returns after a few days.
  • This affects all PVs in the IOC, not just specific ones.
  • I’ve observed the problem using camonitor as well as in client GUIs (CS-Studio).

Please advise thank you,

Alex


References:
IOC PVs intermittently flicker between values and LINK INVALID Tran, Phi Dung via Tech-talk

Navigate by Date:
Prev: IOC PVs intermittently flicker between values and LINK INVALID Tran, Phi Dung via Tech-talk
Next: 4-wire sensing device Sintschuk, Michael via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  <20252026 
Navigate by Thread:
Prev: IOC PVs intermittently flicker between values and LINK INVALID Tran, Phi Dung via Tech-talk
Next: 4-wire sensing device Sintschuk, Michael via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  <20252026 
ANJ, 19 Mar 2026 · Home · News · About · Talk · Base · Modules · Extensions ·
· Distributions · Download · Documents · Links · Licensing ·