Is anyone using an Allen Bradley 6008-SV2R VME Scanner Module
with the Motorola MVME177?
The VME Scanner was verified to be working with an MVME167 by
an exceptionally helpful bunch at Argonne.
The IOC hangs during iocInit. I went into the drvAb.c
source and put in various traces and found the following:
> drvAb: init() > drvAb: ab_driver_init >
drvAb: ab_driver_init PASSED devRegisterAddress > drvAb:
ab_driver_init PASSED devConnectInterrupt > drvAb: ab_driver_init
PASSED devEnableInterrupt > drvAb: link_init > drvAb: link 0,
powerup... > drvAb: link_init, plink->vme_addr=F0C00000 > drvAb:
link_init, p6008->sc_intr=F0C00FFC > sc_lock > drvAb: sc_waitcmd,
plink->vme_addr=F0C00000 > sc_waitcmd > drvAb: sc_waitcmd,
plink->ab_cmd_sem: 1EA382C timeout: 60
The IOC hangs when executing this line of c-code in the
sc_waitcmd function -
status =
semTake(plink->ab_cmd_sem,sysClkRateGet());
We are running EPICS release R3.13.0.beta11
under Solaris 2.5.1 with a SUN ULTRA 30.