1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  <20162017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  <20162017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Error in interfacing gigE camera make: Balser
From: [email protected]
To: [email protected]
Date: Mon, 8 Aug 2016 12:30:38 +0530
Hi,
   I am trying to start an epics driver for Basler scA-1390-17gc camera.
I copied the github repository from
https://github.com/sesamecs/basler-gige.git

I installed pylon3 in /opt directory and started camera with Pylonveiwer.

But when I start epics driver from the above repository following error
messages are shown.
Exception: Failed to write enumeration value. Enum entry is not
writableUnable to initialize driver thread
Unable to read BOC03-DI-CAM1:getExposure: Driver thread is unable to read
Unable to read BOC03-DI-CAM1:getGain: Driver thread is unable to read
Unable to read BOC03-DI-CAM1:getHeight: Driver thread is unable to read
Unable to read BOC03-DI-CAM1:getSize: Driver thread is unable to read
Unable to read BOC03-DI-CAM1:getOffsetY: Driver thread is unable to read
Unable to read BOC03-DI-CAM1:getWidth: Driver thread is unable to read
Unable to read BOC03-DI-CAM1:getGainAuto: Driver thread is unable to read
Unable to read BOC03-DI-CAM1:getOffsetX: Driver thread is unable to read
Unable to read BOC03-DI-CAM1:getTriggerSource: Driver thread is unable to
read

apart from these I am also getting error
"../../../src/ioc/rsrv/online_notify.c: CA beacon (send to
"127.0.0.1:5065") error was "Connection refused"
Please duide me how to start this epics driver.
Thank you


Replies:
Re: Error in interfacing gigE camera make: Balser Mark Rivers

Navigate by Date:
Prev: Re: CA connection problems between VxWorks and Windows Michael Davidsaver
Next: Re: Epics-Digitizer Communication Hulusi Öz
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  <20162017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: CA connection problems between VxWorks and Windows Michael Davidsaver
Next: Re: Error in interfacing gigE camera make: Balser Mark Rivers
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  <20162017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 31 Oct 2016 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·