On Monday 12 February 2007 14:38, Benjamin Franksen wrote:
> being in the final stages of the process to convert an application from
> 3.13 to 3.14, I have just noted that the latest version of the sequencer
> (2.0.11) does not contain the built-in routines pvPutAsync,
> pvPutComplete, and pvPutWait, which have been added to the 3.13
> compatible branch around version 1.9.6 or so.
After taking a closer look, I see that at least pvPutComplete seems to exist
in seq-2.0.11, although it is undocumented.
> Have they been renamed to something else? Or have they never been in the
> 2.0 branch? If the latter, how do other people solve the problem of
> finding out reliably whether and when a pvPut has been completely
> executed?
So am I right in assuming that the standard solution is to pvPutComplete
inside the condition of a when-clause? (This could become tedious if you
want to issue many such pvPuts in sequence, where each one should only be
issued after teh one before is complete -- you'd need as many additional
states as pvPut actions in the sequence, right?)
Ben
--
"Programming = Mathematics + Murphy's Law" (Dijkstra in EWD1008)
- Replies:
- RE: Sequencer problem Mark Rivers
- References:
- Sequencer problem Benjamin Franksen
- Navigate by Date:
- Prev:
RE: Sequencer problem Mark Rivers
- Next:
RE: Sequencer problem Mark Rivers
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
<2007>
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
RE: Sequencer problem Mark Rivers
- Next:
RE: Sequencer problem Mark Rivers
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
<2007>
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
|