1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Two EDM questions
From: "Szalata, Zenon M." <[email protected]>
To: "EPICS Techtalk" <[email protected]>
Date: Tue, 10 Mar 2009 16:39:07 -0700
1. I was asked to present data in an EDM screen as a bar graph.  That is, the bars start at zero and extend to the value for that particular point; it can be positive or negative.    I need to use auto scale.  Now, I tried setting trace type as "needles", which gives me a bar graph, but it chooses some arbitrary negative baseline from which bars for all points are drawn.  The baseline it chose is somewhat below the lowest point.  Is there a way to produce a "true" bar graph in EDM which might look something like this?

               x
               |    x
               |    |   x
               |    |   |
   0 ------------------------
                  |   |    |
                  x   |    x
                      x

2. I would like to use the UpDown button control.  I have connected it to a control PV which is the VAL in a ao record.  I have assumed that right and left buttons as referred to in the online help are mouse buttons.  Perhaps, they are not.  I want to use the UpDown button to increment or decrement the control PV.  I only can get the drop down menu, which has entries like Save, Restore, etc.  How does one use it to increment/decrement?

Any suggestion will be much appreciated,

Zen


Navigate by Date:
Prev: Re: Looking for feedback on what epics users require Claude Saunders
Next: Re: Problem with cothread-1-12 on MacOSX (Leopard) Juan Carlos Guzman
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: Looking for feedback on what epics users require Emmanuel Mayssat
Next: epics for stanford amp or Iseg supply Leicester, PJ (Pete)
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  <20092010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 31 Jan 2014 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·