1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019 
<== Date ==> <== Thread ==>

Subject: LabVIEW EPICS I/O Server
From: Philip Taylor <pbt@observatorysciences.co.uk>
To: EPICS tech-talk <tech-talk@aps.anl.gov>
Date: Mon, 15 Mar 2010 14:26:45 +0000
I am trying to use the "native" (NI-supplied) EPICS I/O Server support for LabVIEW 2009 without the LabVIEW Datalogging and Supervisory Control (DSC) module.

I followed the relevant download and installation instructions, as shown in this page:
http://zone.ni.com/devzone/cda/tut/p/id/10812

Its worth mentioning that step 5 as shown on that page (and the file 'epicsreadme.txt') is identical to Step 2. I assume this is an error and should in fact state that a further software installation is to be done from the .msi file in folder EPICS_LVSupp_90?

Anyway, having performed the installation and restarted the National Instruments Variable Engine, I right-click on 'My Computer' target in a new Project window, select 'New>I/O Server' from the shortcut menu, select 'EPICS Client' option (this does appear) and finally click the 'Continue..' button.

A 'Configure EPICS Client I/O Server' dialog box should appear. But for me, nothing happens at all after I click the 'Continue' button. so I cannot configure an EPICS I/O Server.

I have repeated this installation now on 3 separate PCs, all behave the same. All are running LabVIEW 2009 on Windows XP.

Has anyone succeeded in configuring an EPICS I/O Server for LabVIEW 2009 without the Datalogging and Supervisory Control module?

Philip Taylor


===============================================================================


Philip Taylor                       email : pbt@observatorysciences.co.uk
Observatory Sciences Ltd,           Web   : http://www.observatorysciences.co.uk
8 Sussex Innovation Centre          Phone : (UK)+(0)1223-655603 (VoIP)
Science Park Square                         (UK)+(0)1273-704759 (landline)
University of Sussex                        (UK)+(0)7913-720806 (mobile)
Falmer, BRIGHTON.
BN1 9SB
U.K.

===============================================================================
Replies:
RE: LabVIEW EPICS I/O Server Pawel Kowalski - BiRa Systems Inc.

Navigate by Date:
Prev: INP field length Steve Kinder
Next: RE: LabVIEW EPICS I/O Server Pawel Kowalski - BiRa Systems Inc.
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019 
Navigate by Thread:
Prev: Re: INP field length Dirk Zimoch
Next: RE: LabVIEW EPICS I/O Server Pawel Kowalski - BiRa Systems Inc.
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019 
ANJ, 02 Sep 2010 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·