Hi Mark,
You showed me how to initialize a longout record from a hardware register at iocInit time. I implemented that, as you suggested by creating my version of the virtual function readInt32, and it works fine.
I now have a related question.
How can I modify the contents of a longout record from the low level driver code at run time? I am developing a low level asyn driver derived from asynPortDriver class and it became of interest to me to do that. I think that I could accomplish this using dbAccess routines, but that seems somewhat inelegant.
Thanks in advance,
Zen