EPICS Controls Argonne National Laboratory

Experimental Physics and
Industrial Control System

1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  <20132014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  <20132014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Communications with serial/LAN devices not using string oriented data
From: Rod Nussbaumer <[email protected]>
To: epics Techtalk <[email protected]>
Date: Thu, 23 May 2013 16:32:29 -0700
Hi All.

We have been asked to provide support for a device that communicates serially using packets of binary data. Ordinarily for such tasks I would use streamDevice, but the command protocol for this device (a CPI RF amplifier) is all binary, not strings, and even includes the requirement to byte stuff when framing characters are in the packet payload, as well as compute checksums on the packets. Any recommendations about how to approach this kind of problem? There are a LOT of different commands required to operate this device.

Thanks

Rod Nussbaumer
ISAC Controls, TRIUMF
Vancouver, Canada

Replies:
Re: Communications with serial/LAN devices not using string oriented data Eric Norum
Re: Communications with serial/LAN devices not using string oriented data Zenon Szalata
Re: Communications with serial/LAN devices not using string oriented data Andrew Johnson

Navigate by Date:
Prev: Re: modbus driver disconnect/rewrite poll time Zenon Szalata
Next: Re: Communications with serial/LAN devices not using string oriented data Eric Norum
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  <20132014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: modbus driver disconnect/rewrite poll time Zenon Szalata
Next: Re: Communications with serial/LAN devices not using string oriented data Eric Norum
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  <20132014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 20 Apr 2015 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·