1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: AW: Siemens S7-300 PLC and EPICS
From: Rekow, Jens <[email protected]>
To: Florian Feldbauer <[email protected]>, EPICS Tech Talk <[email protected]>
Date: Tue, 23 May 2017 11:48:35 +0200
Hi Florian,

The most convenient way for us has been using s7nodave support for example like in this tutorial [1].
The advantage is that you don't need additional programming on the PLC side. And if you have a S7-300 CPU with DN/DP you don't need an additional communication module.

Regards,
Jens

[1] http://metis.ipfn.ist.utl.pt/index.php?title=FUSION_Collaborations/ESTHER/Slow_Control/EPICS_%26_Siemens_PLC_Tutorial





-----Ursprüngliche Nachricht-----
Von: [email protected] [mailto:[email protected]] Im Auftrag von Florian Feldbauer
Gesendet: Dienstag, 23. Mai 2017 11:17
An: EPICS Tech Talk
Betreff: Siemens S7-300 PLC and EPICS

Hey all,

for the vacuum system of our tracking detector we want to use a PLC. We decided to use a Siemens S7-300 which should control the pumps, gauges and valves of our system.

The main question now is how to connect the PLC to our EPICS system?
I've seen that the CPU module has PROFINET or PROFIBUS DP interfaces. Is there a device support available for those? Is there a better/easier interface available maybe via an additional communication processor?

Any feedback appreciated!

Best regards,

Florian



--
----------------------------------------
| Dr. Florian Feldbauer                |
|                                      |
| Ruhr-Universität Bochum              |
| Experimentalphysik I AG              |
| Universitätsstr 150                  |
| D-44801 Bochum                       |
|                                      |
| Office: NB 2/134                     |
| Phone:  (+49)234 / 32-23563          |
----------------------------------------



References:
Siemens S7-300 PLC and EPICS Florian Feldbauer

Navigate by Date:
Prev: Re: Force TCP/IP reconnect from Asyn/Streamdevice Torsten Bögershausen
Next: Re: Siemens S7-300 PLC and EPICS Remi FAURE
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Siemens S7-300 PLC and EPICS Florian Feldbauer
Next: Re: Siemens S7-300 PLC and EPICS Remi FAURE
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024 
ANJ, 21 Dec 2017 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·