Hi,
still fighting with the motor record...
I get a strange error message at startup of my IOC:
asynPortDriver:setDoubleParam: port=port1 error setting parameter 19 in list
0, wrong type
asynMotorController:writeFloat64 error, status=8 axis=0, function=19,
value=0.000000
devMotorAsyn::asynCallback: m1 pasyn{Float64,Int32}->write returned <empty
error message>
In my parameter list the number 19 is motorClosedLoop, which indeed is an
int32 parameter. I'm using basic_asyn_motor.db to setup the motor record.
What goes wrong here?
Regards
Jörn