1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: Recommendations for EPICS Based Data Acquisition System
From: Heinz Junkes <[email protected]>
To: Matt Rippa <[email protected]>
Cc: Rolando Rogers <[email protected]>, Talk EPICS Tech <[email protected]>
Date: Thu, 7 Dec 2017 15:13:00 +0100
Aloha Matt,

I am still using (buying) VMEbus stuff.

I am happy with

MVME6100 (alternative MVME2500)
Digitizer Struck SIS16
MAXv motor controller
Highland waveform generator

Running RTEMS 5 with EPICS 7 on them.

Heinz


> On 6. Dec 2017, at 21:54, Matt Rippa <[email protected]> wrote:
> 
> Aloha,
> 
> I'm looking for your recommendations on the latest data acquisition
> hardware, compatible with EPICS.
> 
> Our Secondary Mirror system at Gemini has a 1 meter diameter,
> 55 kg mass. There's 3 degrees of freedom and a 5 kHz control loop.
> The system was designed in the 90's by Lockheed Martin, based on
> a DOS PC with an ISA backplane (PICMG 1.0) and a DSP data
> acquisition board with 16 bit ADC's and DAC's. The DOS PC interfaces
> with an EPICS IOC via Reflected Memory. 
> 
> In 2010 I did a conceptual redesign based on a Hytec Blade 9010 using
> IP cards and an Intel CPU running RTEMS. Today it seems FPGA's are
> a popular choice for data acquisition. Perhaps a Xylinx zynq solution?
> Would anyone still consider VME?
> 
> I have no requirement for 5 kHz EPICS control.  Although that's intriguing.
> 
> Thanks for your time.
> 
> -Matt

Attachment: smime.p7s
Description: S/MIME cryptographic signature


References:
Recommendations for EPICS Based Data Acquisition System Matt Rippa

Navigate by Date:
Prev: Re: Macro for ImageJ running in headless mode for the AreaDetector plugin? Ralph Lange
Next: Re: Recommendations for EPICS Based Data Acquisition System Mark Rivers
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Recommendations for EPICS Based Data Acquisition System Matt Rippa
Next: Re: Recommendations for EPICS Based Data Acquisition System Mark Rivers
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  <20172018  2019  2020  2021  2022  2023  2024 
ANJ, 21 Dec 2017 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·