1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: RE: Mythen M1K - Low fps
From: Mark Rivers <[email protected]>
To: 'Nilson Pereira' <[email protected]>, "[email protected]" <[email protected]>
Date: Thu, 15 Feb 2018 17:31:23 +0000
Hi Nilson,

When you say it is dropping frames, can you be more explicit?  Can you tell where the frames are being dropped, i.e. between the detector and the IOC, or in an IOC plugin?

What plugins are you running in this IOC?

Are they configured with blocking=Enabled or Disabled?

What queue size are the plugins using?

Mark




> -----Original Message-----
> From: [email protected] [mailto:[email protected]] On Behalf
> Of Nilson Pereira
> Sent: Thursday, February 15, 2018 10:50 AM
> To: [email protected]
> Subject: Mythen M1K - Low fps
> 
> Hello everyone,
> 
> I started to work with a Dectris strip Detector Mythen2 X 1K and I am
> using the Mythen module from AreaDetector. This detector can reach
> 1000fps, however the IOC starts to drop frames with frequencies higher
> than 100fps.
> 
> Has anyone experience this limitation with this type of detector?
> To avoid network issues, I have a straight network connection between
> the PC and detector.
> 
> I also noticed that the IOC only requests 1 frame at a time when it
> could (according to the manual) requests multiples frames to avoid
> communication overheads. Has anyone tried implementing this?
> 
> My versions:
> - Ubuntu 16.04
> - EPICS base 3.15.5
> - ADCore 2-6
> - ADMythen 2-0
> 
> 
> 
> ________________________________
> 
> Helmholtz-Zentrum Berlin für Materialien und Energie GmbH
> 
> Mitglied der Hermann von Helmholtz-Gemeinschaft Deutscher Forschungszentren e.V.
> 
> Aufsichtsrat: Vorsitzender Dr. Karl Eugen Huthmacher, stv. Vorsitzende Dr. Jutta Koch-
> Unterseher
> Geschäftsführung: Prof. Dr. Bernd Rech (kommissarisch), Thomas Frederking
> 
> Sitz Berlin, AG Charlottenburg, 89 HRB 5583
> 
> Postadresse:
> Hahn-Meitner-Platz 1
> D-14109 Berlin
> 
> http://www.helmholtz-berlin.de

Replies:
Re: Mythen M1K - Low fps Nilson Pereira
References:
Mythen M1K - Low fps Nilson Pereira

Navigate by Date:
Prev: Re: PMAC asyn autoconnect issue Bruno Martins
Next: RE: PMAC asyn autoconnect issue Mark Rivers
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: RE: Mythen M1K - Low fps Mark Engbretson
Next: Re: Mythen M1K - Low fps Nilson Pereira
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
ANJ, 15 Feb 2018 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·