1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: Radiation Monitors
From: "Dunning, Michael" <[email protected]>
To: "Andrew C. Starritt" <[email protected]>
Cc: EPICS Tech Talk <[email protected]>
Date: Fri, 20 Apr 2018 08:33:17 -0700
We've been using a Thermo FHT 6020 in production for around 9 months
now; as far as I know it has been reliable.  I believe our Rad Physics
group is happy with it as they've purchased several more and are
planning on installing them soon.
The only downside is that it's a bit slow.  If you want to read from
multiple channels it can take several seconds, although with a single
channel (or maybe two) it can update once per second.
EPICS integration was straightforward.  I wrote an asynPortDriver for
it, but StreamDevice would probably work fine for basic functionality.


Mike



Michael Dunning
SLAC National Accelerator Laboratory
2575 Sand Hill Road
Menlo Park, CA 94025
(650) 926-5200


On Thu, Apr 19, 2018 at 9:37 PM, Andrew C. Starritt
<[email protected]> wrote:
> Dear tech-talkers,
>
> At the Australian Synchrotron, we have started an initiative to upgrade our
> radiation monitors.
> We are currently investigating Thermo Scientific FHT 6020, Ludlum 375 and
> Berthold models.
>
> We would in interested in hearing about your experience with radiation
> monitor in general and
> the above models in particular, especially with respect to integrating these
> into EPICS.
>
> Regards
>
>
> Andrew C. Starritt | Leader Accelerator and Support Systems | Australian
> Synchrotron
> p: (03) 8540 4164 | f: (03) 8540 4200
> [email protected] | www.synchrotron.org.au
> 800 Blackburn Road, Clayton, Victoria 3168
>
>
>

References:
Radiation Monitors Andrew C. Starritt

Navigate by Date:
Prev: Re: Possible deadlock issue with asyn layer? Davis, Mark
Next: ADPointGrey with AD3-2, and base-7.0.1.1 Gofron, Kazimierz
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Radiation Monitors Andrew C. Starritt
Next: Re: Radiation Monitors Heinz Junkes
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
ANJ, 23 Apr 2018 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·