1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  <20202021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  <20202021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: quadEM R9-3 now available
From: Mark Rivers via Tech-talk <tech-talk at aps.anl.gov>
To: "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov>
Date: Mon, 2 Mar 2020 21:37:04 +0000

Folks,

 

quadEM R9-3 is now available. 

 

This is from the R9-3 release notes:

 

************************************

- This version of quadEM requires ADCore R3-8 or later.

 

- Previous versions of quadEM will not work with ADCore R3-8 or later because the Acquire parameter is now implemented in the asynNDArrayDriver base class, rather than being local to quadEM.

 

- Added a new drvNSLS2_IC driver which has independent control of each channel for use with separate ion chambers, for example, rather than a quad electrometer.

 

- drvNSLS_EM: Fixed logic error in turning off data transmission from meter when not acquiring.

 

- iocsh/commonPlugins.iocsh: Fixed names of FFT time series ports.

 

- Added .bob autoconverted files for Phoebus Display Manager.

************************************

 

The home page is here:

http://cars.uchicago.edu/software/epics/quadEM.html

 

The documentation is here:

http://cars.uchicago.edu/software/epics/quadEMDoc.html

 

The release notes are here:

http://cars.uchicago.edu/software/epics/quadEMReleaseNotes.html

 

The software repository is on github.  Releases can be obtained there.

https://github.com/epics-modules/quadEM

 

Let me know of any problems or suggestions.

 

Mark

 

 

 


Navigate by Date:
Prev: RE: pco Camera USB and IEEE interface Ivashkevych, Oksana via Tech-talk
Next: Re: pco Camera USB and IEEE interface Bradnick, Ben (Tessella, RAL, TEC) via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  <20202021  2022  2023  2024 
Navigate by Thread:
Prev: RE: Streams Support for Varian Dual Mark Rivers via Tech-talk
Next: FW: EPICS on windows10 Debian Shell Alfio Rizzo via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  <20202021  2022  2023  2024 
ANJ, 09 Mar 2020 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·