Experimental Physics and Industrial Control System
|
Area any errors being thrown in the iocConsole? Is this camera on a shared network cable or on a dedicated private network? Is the ethernet MTU setting (jumbo packets) as large as the ethernet adapter supports?
From: Tech-talk <tech-talk-bounces at aps.anl.gov> On Behalf Of
Jong Woo Kim via Tech-talk
Sent: Monday, October 5, 2020 3:32 PM
To: tech-talk at aps.anl.gov
Subject: Inconsistency of image rate in ADVimba
I found that the Image rate (PV:13VMB1:cam1:ArrayRate_RBV) varies randomly.
When I set the Frame rate to be 10 and ROI to be 2464x2056 (full image size), The image rate is sometimes 22 or 2 or 8. There is also no tendency with ROI. The camera is Mako. Do you have any idea
about this issue?
|
- Replies:
- RE: Inconsistency of image rate in ADVimba Mark Rivers via Tech-talk
- References:
- Inconsistency of image rate in ADVimba Jong Woo Kim via Tech-talk
- Navigate by Date:
- Prev:
Inconsistency of image rate in ADVimba Jong Woo Kim via Tech-talk
- Next:
RE: Inconsistency of image rate in ADVimba Mark Rivers via Tech-talk
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
<2020>
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
Inconsistency of image rate in ADVimba Jong Woo Kim via Tech-talk
- Next:
RE: Inconsistency of image rate in ADVimba Mark Rivers via Tech-talk
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
<2020>
2021
2022
2023
2024
|
ANJ, 05 Oct 2020 |
·
Home
·
News
·
About
·
Base
·
Modules
·
Extensions
·
Distributions
·
Download
·
·
Search
·
EPICS V4
·
IRMIS
·
Talk
·
Bugs
·
Documents
·
Links
·
Licensing
·
|