1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  <20202021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  <20202021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: EPICS7 and RTEMS5.1 Testing
From: Matt Rippa via Tech-talk <tech-talk at aps.anl.gov>
To: "Johnson, Andrew N." <anj at anl.gov>
Cc: EPICS tech-talk <tech-talk at aps.anl.gov>
Date: Fri, 30 Oct 2020 16:36:58 -1000
Hi Andrew,

Okay, thanks, I'll wait to hear back. The pc686 and others mentioned are what we want to test.

-Matt

On Fri, Oct 30, 2020 at 1:30 PM Johnson, Andrew N. <anj at anl.gov> wrote:
Hi Matt,

On Oct 30, 2020, at 4:59 PM, Matt Rippa via Tech-talk <tech-talk at aps.anl.gov> wrote:

I'd like to start testing EPICS7 on RTEMS5.1. I think these are the latest versions slated for support. Is there guidance setting this up from the EPICS community? If not, I pretty much know what to do, but I'll be winging it a little --merging rtems specific instructions with epics specific instructions.

My target bsp's include pc386, beatnik, 3100 and motorola_shared (mvme_2700).

That would be great, but unfortunately we aren’t quite ready for testers yet. Right now we have 3 different versions of the RTEMS-5 port that need to be reconciled and merged into the 7.0 branch. There is a meeting of the Core Developers group on Wednesday when I plan to discuss doing that, assuming all 3 of the relevant developers are able to attend (please check the Agenda guys!), so hopefully it won’t be too much longer.

I will try to remember to let you and the community know as soon as we have the RTEMS-5 port merged.

BTW RTEMS-5 now provides a pc686 BSP, would you be able to run that instead of the pc386 or do you need the older one for the particular CPU boards you’re using?

- Andrew

-- 
Complexity comes for free, simplicity you have to work for.


References:
EPICS7 and RTEMS5.1 Testing Matt Rippa via Tech-talk
Re: EPICS7 and RTEMS5.1 Testing Johnson, Andrew N. via Tech-talk

Navigate by Date:
Prev: Re: Archiver Appliance PVs never connect to be archived, always "Initial Sampling" Jeong Han Lee via Tech-talk
Next: Accessing info fields via CA/PVA Simon Rose via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  <20202021  2022  2023  2024 
Navigate by Thread:
Prev: Re: EPICS7 and RTEMS5.1 Testing Johnson, Andrew N. via Tech-talk
Next: Accessing info fields via CA/PVA Simon Rose via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  <20202021  2022  2023  2024 
ANJ, 02 Nov 2020 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·