1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
<== Date ==> <== Thread ==>

Subject: RE: New Radiation Monitor options
From: "Baker, Keith \(DLSLtd, RAL, LSCI\) via Tech-talk" <tech-talk at aps.anl.gov>
To: tech-talk <tech-talk at aps.anl.gov>
Date: Thu, 29 Jul 2021 07:59:28 +0000
Thanks, Brendan and Andrew.
Looks like we have two more monitors we should look at more closely. I'll point our Health Physics team at these and then come back to you for EPICS drivers if we want to go ahead with one.

My revised summary is:
Health Physics Instruments (HPI) 6016 Area Radiation Monitors (Used in NSLS-II. Drivers available).
Thermo Scientific FHT 6020 (Drivers developed at SLAC and the FHI FEL. Initially reported slow communications but APS report ~0.05s response time).
Ludlum 375 (In use at Aus Synch with Asyn Port driver they developed).
Berthold (No EPICS support mentioned).

Regards,
Keith Baker
Diamond Light Source

-----Original Message-----
From: STARRITT, Andrew <andrews at ansto.gov.au> 
Sent: 29 July 2021 02:48
To: EPICS Tech Talk (tech-talk at aps.anl.gov) <tech-talk at aps.anl.gov>
Cc: Chandler, Brendan <bchandler at anl.gov>; Baker, Keith (DLSLtd,RAL,LSCI) <keith.baker at diamond.ac.uk>
Subject: RE: New Radiation Monitor options [SEC=UNOFFICIAL]

Hi Keith, Brendan,

At the Australian Synchrotron, in the end we went the Ludlum 375.
And we developed an EPICS Asyn Port driver which I am more than happy to share if you, if you select the Ludlum.

Regards

UNOFFICIAL

-----Original Message-----
From: Tech-talk <tech-talk-bounces at aps.anl.gov> On Behalf Of Chandler, Brendan via Tech-talk
Sent: Thursday, 29 July 2021 5:59 AM
To: tech-talk <tech-talk at aps.anl.gov>; Baker, Keith (DLSLtd,RAL,LSCI) <keith.baker at diamond.ac.uk>
Subject: Re: New Radiation Monitor options

CAUTION, EXTERNAL EMAIL: This message has come from a source outside of ANSTO. Do not take action, click links or open attachments unless you recognise and trust the source of this email and know the content is safe. Please report suspicious emails to servicedesk at ansto.gov.au as an attachment.

Hi Keith,

At APS we've been evaluating the Thermo FHT6020 and I haven't seen the performance issues mentioned in the Australian Synchrotron thread.  I tried timing 100 requests to our FHT6020 device, alternating beween channels 1 and 2 each time, and it averaged 0.05 seconds per request, doing the entire 100 in about 5 seconds.  Maybe Thermo Fischer has updated the firmware or there was some other issue since then?

I've made a streamdevice based IOC to talk to the FHT6020 and could share with you if you're interested.  Similarly, I have a streamdevice IOC for the Mirion DRM-3000 radiation monitor if interested.

Brendan


________________________________________
From: Tech-talk <tech-talk-bounces at aps.anl.gov> on behalf of Baker, Keith (DLSLtd, RAL, LSCI) via Tech-talk <tech-talk at aps.anl.gov>
Sent: Wednesday, July 28, 2021 10:36
To: tech-talk
Subject: New Radiation Monitor options

Hello,
We are looking at the Berthold LB6419 Neutron and Gamma Radiation Monitor as a possible replacement for our old obsolete ones.
I've been told these are in use at PETRA. Can anyone confirm that and has anyone already developed EPICS support for this model or similar?

I see that a similar message about new Radiation Monitors was posted by the Australian Synchrotron in 2018. I think the summary of responses was,

Health Physics Instruments (HPI) 6016 Area Radiation Monitors (Used in NSLS-II. Drivers available) Thermo Scientific FHT 6020 (Drivers developed at SLAC and the FHI FEL, but the device is quite slow apparently. "read from multiple channels can take several seconds". I assume that means several values.) Ludlum 375 (No EPICS support mentioned.) Berthold (No EPICS support mentioned.)

Any other suggestions would be welcome.
Thanks.
Keith Baker
Diamond Light Source




--

This e-mail and any attachments may contain confidential, copyright and or privileged material, and are for the use of the intended addressee only. If you are not the intended addressee or an authorised recipient of the addressee please notify us of receipt by returning the e-mail and do not use, copy, retain, distribute or disclose the information in or attached to the e-mail.
Any opinions expressed within this e-mail are those of the individual and not necessarily of Diamond Light Source Ltd.
Diamond Light Source Ltd. cannot guarantee that this e-mail or any attachments are free from viruses and we cannot accept liability for any damage which you may sustain as a result of software viruses which may be transmitted in or with the message.
Diamond Light Source Limited (company no. 4375679). Registered in England and Wales with its registered office at Diamond House, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom


Navigate by Date:
Prev: RE: New Radiation Monitor options [SEC=UNOFFICIAL] STARRITT, Andrew via Tech-talk
Next: Stream device: Reading values from two almost identical input strings using I/O intr Nicklas Bjärnhall Prytz via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
Navigate by Thread:
Prev: Re: New Radiation Monitor options Chandler, Brendan via Tech-talk
Next: Drivers for Thorlabs camera, Gentec power meter? Feister, Scott via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
ANJ, 29 Jul 2021 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·