I'm using areaDetector-master with ADAravis R2-2 and ADGeniCam R1-7 to control a Basler raL12288-8gm. Continuous and single image modes work fine, but when I try to use Multiple image mode and acquire 10 images, I get the following error in my IOC:
** (process:14182): CRITICAL **: 15:24:34.136: arv_gc_integer_get_value: assertion 'error == NULL || *error == NULL' failed 2021/10/14 15:24:34.148 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576 2021/10/14 15:24:34.158 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576 2021/10/14 15:24:34.168 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576 2021/10/14 15:24:34.178 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576 2021/10/14 15:24:34.188 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576 2021/10/14 15:24:34.198 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576 2021/10/14 15:24:34.208 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576 2021/10/14 15:24:34.218 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576 2021/10/14 15:24:34.228 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576 2021/10/14 15:24:34.238 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576 Please let me know what further information may be useful. Thanks so much, Katie
| ||||||||||||||
ANJ, 14 Oct 2021 |
·