1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
<== Date ==> <== Thread ==>

Subject: RE: ADAravis multiple image mode fail for Basler raL12288-8gm
From: Mark Rivers via Tech-talk <tech-talk at aps.anl.gov>
To: 'David Vine' <dvine at sigray.com>
Cc: "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov>
Date: Tue, 19 Oct 2021 19:21:47 +0000

Did you verify that this camera does not support MultiFrame?

 

Mark

 

 

From: Tech-talk <tech-talk-bounces at aps.anl.gov> On Behalf Of David Vine via Tech-talk
Sent: Tuesday, October 19, 2021 2:06 PM
To: tech-talk at aps.anl.gov
Subject: RE: ADAravis multiple image mode fail for Basler raL12288-8gm

 

Hi Mark,

 

We fixed the problem by changing in ADAravis.cpp:


    } else if (imageMode == ADImageMultiple) {
...
        arv_camera_set_acquisition_mode(this->camera, ARV_ACQUISITION_MODE_MULTI_FRAME, err.get());

 

to:

    } else if (imageMode == ADImageMultiple) {
...
        arv_camera_set_acquisition_mode(this->camera, ARV_ACQUISITION_MODE_CONTINUOUS, err.get());

 

 

then the acquisition is stopped by:

if ((imageMode == ADImageSingle) ||
                    ((imageMode == ADImageMultiple) &&
                     (numImagesCounter >= numImages))) {
                    this->stopCapture();

 

Thanks,
David

 

On Tue, Oct 19, 2021 at 11:37 AM <tech-talk-request at aps.anl.gov> wrote:

Send Tech-talk mailing list submissions to
        tech-talk at aps.anl.gov

To subscribe or unsubscribe via the World Wide Web, visit
        https://mailman.aps.anl.gov/mailman/listinfo/tech-talk
or, via email, send a message with subject or body 'help' to
        tech-talk-request at aps.anl.gov

You can reach the person managing the list at
        tech-talk-owner at aps.anl.gov

When replying, please edit your Subject line so it is more specific
than "Re: Contents of Tech-talk digest..."
Today's Topics:

   1. RE: ADAravis multiple image mode fail for Basler raL12288-8gm
      (Mark Rivers)
   2. RE: ADAravis multiple image mode fail for Basler raL12288-8gm
      (Mark Rivers)



---------- Forwarded message ----------
From: Mark Rivers <rivers at cars.uchicago.edu>
To: "'Katie Matusik'" <kmatusik at sigray.com>
Cc: "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov>
Bcc: 
Date: Tue, 19 Oct 2021 18:04:17 +0000
Subject: RE: ADAravis multiple image mode fail for Basler raL12288-8gm

Hi Katie,

 

Ø  We updated ADAravis to R2-2-1. The IOC continuously outputs the following lines:

Ø  2021/10/18 12:15:17.557 asynPortDriver:readInt32: function=55, name=POOL_FREE_BUFFERS, value=0
2021/10/18 12:15:18.557 BASLER addr -1 queueRequest priority 0 not lockHolder

Those messages are normal.  I think they are coming because you have enabled ASYN_TRACE_FLOW and/or ASYN_TRACEIO_DRIVER in your st.cmd file.

 

Ø  and when I try to run in Multiple image mode and acquire 20 images, I get the following:

Ø  ** (process:200574): CRITICAL **: 12:15:19.317: arv_gc_integer_get_value: assertion 'error == NULL || *error == NULL' failed

 

It may be that the Basler raL12288-8gm does not support MultiFrame mode.

 

The Basler scA1300-32gm does support it:

 

corvette:ADGenICam/GenICamApp/Db>grep -U10 AcquisitionMode Basler-scA1300-32gm.template

record(mbbo, "$(P)$(R)GC_AcquisitionMode") {

  field(DTYP, "asynInt32")

  field(OUT,  "@asyn($(PORT),$(ADDR=0),$(TIMEOUT=1))GC_E_AcquisitionMode")

  field(DOL,  "0")

  field(ZRST, "SingleFrame")

  field(ZRVL, "0")

  field(ONST, "MultiFrame")

  field(ONVL, "1")

  field(TWST, "Continuous")

  field(TWVL, "2")

  field(DISA, "0")

}

 

However, the Basler does not:

 

corvette:ADGenICam/GenICamApp/Db>grep -U10 AcquisitionMode Basler_piA640_210gm.template

record(mbbo, "$(P)$(R)GC_AcquisitionMode") {

  field(DTYP, "asynInt32")

  field(OUT,  "@asyn($(PORT),$(ADDR=0),$(TIMEOUT=1))GC_E_AcquisitionMode")

  field(DOL,  "0")

  field(ZRST, "SingleFrame")

  field(ZRVL, "0")

  field(ONST, "Continuous")

  field(ONVL, "1")

  field(DISA, "0")

}

 

Note that MultiFrame is not in the list of supported modes.

 

You should look at the template file for your camera and see if MultiFrame is supported.

 

Mark

 

 

From: Katie Matusik <kmatusik at sigray.com>
Sent: Monday, October 18, 2021 2:19 PM
To: Mark Rivers <rivers at cars.uchicago.edu>
Cc: tech-talk at aps.anl.gov
Subject: Re: ADAravis multiple image mode fail for Basler raL12288-8gm

 

Hi Mark,

We updated ADAravis to R2-2-1. The IOC continuously outputs the following lines:

2021/10/18 12:15:17.557 asynPortDriver:readInt32: function=55, name=POOL_FREE_BUFFERS, value=0
2021/10/18 12:15:18.557 BASLER addr -1 queueRequest priority 0 not lockHolder
2021/10/18 12:15:18.557 asynManager::portThread port=BASLER callback
2021/10/18 12:15:18.557 BASLER addr -1 queueRequest priority 0 not lockHolder
2021/10/18 12:15:18.557 asynManager::portThread port=BASLER callback
2021/10/18 12:15:18.557 asynPortDriver:readFloat64: function=57, name=POOL_USED_MEMORY, value=0.000000
2021/10/18 12:15:18.557 BASLER addr -1 queueRequest priority 0 not lockHolder
2021/10/18 12:15:18.557 asynManager::portThread port=BASLER callback
2021/10/18 12:15:18.557 asynPortDriver:readInt32: function=54, name=POOL_ALLOC_BUFFERS, value=0
2021/10/18 12:15:18.557 BASLER addr -1 queueRequest priority 0 not lockHolder
2021/10/18 12:15:18.557 asynManager::portThread port=BASLER callback
2021/10/18 12:15:18.557 asynPortDriver:readInt32: function=55, name=POOL_FREE_BUFFERS, value=0
2021/10/18 12:15:19.316 BASLER addr -1 queueRequest priority 0 not lockHolder
2021/10/18 12:15:19.316 asynManager::portThread port=BASLER callback

 

and when I try to run in Multiple image mode and acquire 20 images, I get the following:

** (process:200574): CRITICAL **: 12:15:19.317: arv_gc_integer_get_value: assertion 'error == NULL || *error == NULL' failed
2021/10/18 12:15:19.319 ADGenICam::writeInt32 function=8, value=1, status=0
2021/10/18 12:15:19.319 ADAravis:writeInt32: function=8 ACQUIRE, value=1
2021/10/18 12:15:19.329 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.339 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.349 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.359 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.369 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.379 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.389 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.399 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.409 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.419 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.429 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.439 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.449 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.459 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.469 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.479 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.489 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.499 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.509 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.519 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.535 ADAravis:run: acquisition completed

 

Single and continuous image modes work as expected. 


Thanks!

Katie

 

 

On Thu, Oct 14, 2021 at 5:31 PM Mark Rivers <rivers at cars.uchicago.edu> wrote:

Hi Katie,

 

Can you try updating to ADAravis R2-2-1?  That provides improved error message handling so we may be able to see where in the ADAravis driver the error is occurring.

 

Mark

 

 

From: Tech-talk <tech-talk-bounces at aps.anl.gov> On Behalf Of Katie Matusik via Tech-talk
Sent: Thursday, October 14, 2021 5:26 PM
To: tech-talk <
tech-talk at aps.anl.gov>
Subject: ADAravis multiple image mode fail for Basler raL12288-8gm

 

I'm using areaDetector-master with ADAravis R2-2 and ADGeniCam R1-7 to control a Basler raL12288-8gm. Continuous and single image modes work fine, but when I try to use Multiple image mode and acquire 10 images, I get the following error in my IOC:

** (process:14182): CRITICAL **: 15:24:34.136: arv_gc_integer_get_value: assertion 'error == NULL || *error == NULL' failed
2021/10/14 15:24:34.148 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.158 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.168 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.178 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.188 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.198 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.208 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.218 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.228 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.238 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576

 

Please let me know what further information may be useful.

Thanks so much,

Katie

 

 

Image removed by sender.

 

This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error, please notify the system manager. This message contains confidential information and is intended only for the individual named. If you are not the named addressee, you should not disseminate, distribute or copy this email. Please notify the sender immediately by email if you have received this email by mistake and delete this email from your system. If you are not the intended recipient, you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited


 

--

Katie Matusik

Systems Engineer

5750 Imhoff Drive, Suite I

Concord, CA 94520 USA

Office: 1 (925) 326 - 7926

 

Image removed by sender.

 

This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error, please notify the system manager. This message contains confidential information and is intended only for the individual named. If you are not the named addressee, you should not disseminate, distribute or copy this email. Please notify the sender immediately by email if you have received this email by mistake and delete this email from your system. If you are not the intended recipient, you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited




---------- Forwarded message ----------
From: Mark Rivers <rivers at cars.uchicago.edu>
To: "'Katie Matusik'" <kmatusik at sigray.com>
Cc: "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov>
Bcc: 
Date: Tue, 19 Oct 2021 18:36:57 +0000
Subject: RE: ADAravis multiple image mode fail for Basler raL12288-8gm

I meant to say:

 

“However, the Basler piA640_210gm does not:”

 

Mark

 

 

 

From: Tech-talk <tech-talk-bounces at aps.anl.gov> On Behalf Of Mark Rivers via Tech-talk
Sent: Tuesday, October 19, 2021 1:04 PM
To: 'Katie Matusik' <kmatusik at sigray.com>
Cc: tech-talk at aps.anl.gov
Subject: RE: ADAravis multiple image mode fail for Basler raL12288-8gm

 

Hi Katie,

 

Ø  We updated ADAravis to R2-2-1. The IOC continuously outputs the following lines:

Ø  2021/10/18 12:15:17.557 asynPortDriver:readInt32: function=55, name=POOL_FREE_BUFFERS, value=0
2021/10/18 12:15:18.557 BASLER addr -1 queueRequest priority 0 not lockHolder

Those messages are normal.  I think they are coming because you have enabled ASYN_TRACE_FLOW and/or ASYN_TRACEIO_DRIVER in your st.cmd file.

 

Ø  and when I try to run in Multiple image mode and acquire 20 images, I get the following:

Ø  ** (process:200574): CRITICAL **: 12:15:19.317: arv_gc_integer_get_value: assertion 'error == NULL || *error == NULL' failed

 

It may be that the Basler raL12288-8gm does not support MultiFrame mode.

 

The Basler scA1300-32gm does support it:

 

corvette:ADGenICam/GenICamApp/Db>grep -U10 AcquisitionMode Basler-scA1300-32gm.template

record(mbbo, "$(P)$(R)GC_AcquisitionMode") {

  field(DTYP, "asynInt32")

  field(OUT,  "@asyn($(PORT),$(ADDR=0),$(TIMEOUT=1))GC_E_AcquisitionMode")

  field(DOL,  "0")

  field(ZRST, "SingleFrame")

  field(ZRVL, "0")

  field(ONST, "MultiFrame")

  field(ONVL, "1")

  field(TWST, "Continuous")

  field(TWVL, "2")

  field(DISA, "0")

}

 

However, the Basler does not:

 

corvette:ADGenICam/GenICamApp/Db>grep -U10 AcquisitionMode Basler_piA640_210gm.template

record(mbbo, "$(P)$(R)GC_AcquisitionMode") {

  field(DTYP, "asynInt32")

  field(OUT,  "@asyn($(PORT),$(ADDR=0),$(TIMEOUT=1))GC_E_AcquisitionMode")

  field(DOL,  "0")

  field(ZRST, "SingleFrame")

  field(ZRVL, "0")

  field(ONST, "Continuous")

  field(ONVL, "1")

  field(DISA, "0")

}

 

Note that MultiFrame is not in the list of supported modes.

 

You should look at the template file for your camera and see if MultiFrame is supported.

 

Mark

 

 

From: Katie Matusik <kmatusik at sigray.com>
Sent: Monday, October 18, 2021 2:19 PM
To: Mark Rivers <rivers at cars.uchicago.edu>
Cc: tech-talk at aps.anl.gov
Subject: Re: ADAravis multiple image mode fail for Basler raL12288-8gm

 

Hi Mark,

We updated ADAravis to R2-2-1. The IOC continuously outputs the following lines:

2021/10/18 12:15:17.557 asynPortDriver:readInt32: function=55, name=POOL_FREE_BUFFERS, value=0
2021/10/18 12:15:18.557 BASLER addr -1 queueRequest priority 0 not lockHolder
2021/10/18 12:15:18.557 asynManager::portThread port=BASLER callback
2021/10/18 12:15:18.557 BASLER addr -1 queueRequest priority 0 not lockHolder
2021/10/18 12:15:18.557 asynManager::portThread port=BASLER callback
2021/10/18 12:15:18.557 asynPortDriver:readFloat64: function=57, name=POOL_USED_MEMORY, value=0.000000
2021/10/18 12:15:18.557 BASLER addr -1 queueRequest priority 0 not lockHolder
2021/10/18 12:15:18.557 asynManager::portThread port=BASLER callback
2021/10/18 12:15:18.557 asynPortDriver:readInt32: function=54, name=POOL_ALLOC_BUFFERS, value=0
2021/10/18 12:15:18.557 BASLER addr -1 queueRequest priority 0 not lockHolder
2021/10/18 12:15:18.557 asynManager::portThread port=BASLER callback
2021/10/18 12:15:18.557 asynPortDriver:readInt32: function=55, name=POOL_FREE_BUFFERS, value=0
2021/10/18 12:15:19.316 BASLER addr -1 queueRequest priority 0 not lockHolder
2021/10/18 12:15:19.316 asynManager::portThread port=BASLER callback

 

and when I try to run in Multiple image mode and acquire 20 images, I get the following:

** (process:200574): CRITICAL **: 12:15:19.317: arv_gc_integer_get_value: assertion 'error == NULL || *error == NULL' failed
2021/10/18 12:15:19.319 ADGenICam::writeInt32 function=8, value=1, status=0
2021/10/18 12:15:19.319 ADAravis:writeInt32: function=8 ACQUIRE, value=1
2021/10/18 12:15:19.329 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.339 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.349 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.359 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.369 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.379 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.389 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.399 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.409 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.419 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.429 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.439 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.449 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.459 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.469 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.479 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.489 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.499 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.509 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.519 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/18 12:15:19.535 ADAravis:run: acquisition completed

 

Single and continuous image modes work as expected. 


Thanks!

Katie

 

 

On Thu, Oct 14, 2021 at 5:31 PM Mark Rivers <rivers at cars.uchicago.edu> wrote:

Hi Katie,

 

Can you try updating to ADAravis R2-2-1?  That provides improved error message handling so we may be able to see where in the ADAravis driver the error is occurring.

 

Mark

 

 

From: Tech-talk <tech-talk-bounces at aps.anl.gov> On Behalf Of Katie Matusik via Tech-talk
Sent: Thursday, October 14, 2021 5:26 PM
To: tech-talk <
tech-talk at aps.anl.gov>
Subject: ADAravis multiple image mode fail for Basler raL12288-8gm

 

I'm using areaDetector-master with ADAravis R2-2 and ADGeniCam R1-7 to control a Basler raL12288-8gm. Continuous and single image modes work fine, but when I try to use Multiple image mode and acquire 10 images, I get the following error in my IOC:

** (process:14182): CRITICAL **: 15:24:34.136: arv_gc_integer_get_value: assertion 'error == NULL || *error == NULL' failed
2021/10/14 15:24:34.148 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.158 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.168 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.178 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.188 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.198 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.208 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.218 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.228 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576
2021/10/14 15:24:34.238 ADAravis:processBuffer: w: 12288, h: 1, size: 0, expected_size: 24576

 

Please let me know what further information may be useful.

Thanks so much,

Katie

 

 

Image removed by sender.

 

This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error, please notify the system manager. This message contains confidential information and is intended only for the individual named. If you are not the named addressee, you should not disseminate, distribute or copy this email. Please notify the sender immediately by email if you have received this email by mistake and delete this email from your system. If you are not the intended recipient, you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited


 

--

Katie Matusik

Systems Engineer

5750 Imhoff Drive, Suite I

Concord, CA 94520 USA

Office: 1 (925) 326 - 7926

 

Image removed by sender.

 

This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error, please notify the system manager. This message contains confidential information and is intended only for the individual named. If you are not the named addressee, you should not disseminate, distribute or copy this email. Please notify the sender immediately by email if you have received this email by mistake and delete this email from your system. If you are not the intended recipient, you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited

_______________________________________________
Tech-talk mailing list Tech-talk at aps.anl.gov
https://mailman.aps.anl.gov/mailman/listinfo/tech-talk

 

 

This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error, please notify the system manager. This message contains confidential information and is intended only for the individual named. If you are not the named addressee, you should not disseminate, distribute or copy this email. Please notify the sender immediately by email if you have received this email by mistake and delete this email from your system. If you are not the intended recipient, you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited


References:
RE: ADAravis multiple image mode fail for Basler raL12288-8gm David Vine via Tech-talk

Navigate by Date:
Prev: RE: ADAravis multiple image mode fail for Basler raL12288-8gm David Vine via Tech-talk
Next: Re: Tech-talk Digest, Vol 15, Issue 547 Katie Matusik via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
Navigate by Thread:
Prev: RE: ADAravis multiple image mode fail for Basler raL12288-8gm David Vine via Tech-talk
Next: RE: ADAravis multiple image mode fail for Basler raL12288-8gm Mark Rivers via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  <20212022  2023  2024 
ANJ, 19 Oct 2021 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·