1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 <2021> 2022 2023 2024 | Index | 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 <2021> 2022 2023 2024 |
<== Date ==> | <== Thread ==> |
---|
Subject: | RE: Help with Blackfly FLIR/PointGrey Camera |
From: | Mark L Rivers via Tech-talk <tech-talk at aps.anl.gov> |
To: | "Smith, William" <william.smith at helmholtz-berlin.de> |
Cc: | "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov> |
Date: | Mon, 15 Nov 2021 19:40:36 +0000 |
Is the problem you were having with ADPointGrey resolved once you switched to ADSpinnaker? Mark From: Smith, William <william.smith at helmholtz-berlin.de>
Ah ok I see. I have now got it working with ADSpinnaker. Thanks for your speedy help! Cheers, Will From: Mark L Rivers <rivers at cars.uchicago.edu>
Hi Will,
Ø
I am using Linux, Ubuntu 20.04. I am using ADPointGrey with area detector version 3.1
Ø
I am using the latest version of the SDK spinnaker-2.5.0.80 Those 2 statements are inconsistent. ADPointGrey does not use the Spinnaker SDK, it uses the obsolete FlyCap2 SDK. I suggest you switch from ADPointGrey to ADSpinnaker, which is based on the currently supported Spinnaker SDK. Mark From: Smith, William <william.smith at helmholtz-berlin.de>
Hi Mark, I am using Linux, Ubuntu 20.04. I am using ADPointGrey with area detector version 3.1 I am using the latest version of the SDK spinnaker-2.5.0.80 The camera is model BFLY-PGE-50A2M-CS The problem occurs after a first acquisition in any acquisiton mode. Any subsequent attempts to cause acquisition result in nothing, and error messages saying that the messages have not been written. It works great for
the first acquisition (single, multiple or continuous). I can take multiple/ continuous images without a problem. If I try to take more after stopping I can’t. Best, Will From: Mark L Rivers <rivers at cars.uchicago.edu>
Hi Will, It would help to have some more information. Linux or Windows? ADPointGrey, ADSpinnaker or ADAravis. Which version of the driver? What version of the SDK? What model camera? Can you describe an exact sequence of events which triggers the problem? Mark From: Tech-talk <tech-talk-bounces at aps.anl.gov>
On Behalf Of Smith, William via Tech-talk Hi, I am trying to set up a point FLIR Blackfly camera using the point grey areaDetector support module.
I am able to connect to the camera and take images using the supplied SpinView Software. I am able to connect to the camera using the point grey area detector IOC. I can take 1 image in single mode, multiple images in
multiple mode, or as many images as I like in continuous mode. However, after 1 or two images in single mode, or the group in multiple, or if I press “stop” in continuous mode, I cannot take any more images.
In the IOC I get the following error at the end of the acquisition (in any mode) if there is an error.
If it’s relevant I have packet size set to 1440 (I am not using jumbo frames) Has anybody seen something similar? Can I enable some additional debug to get more information? Is there some additional configuration of my network card I should check? Many thanks, Will
|