Experimental Physics and Industrial Control System
|
If I read the unique id from both plugins and make sure the are the same, how
big is the chance that the data does not match if I read them in two threads
(thread 1: the image, thread 2: the stats information)?
Would the situation improve if I can remove the gateway process?
The one thing that would remove the issue: Use pvAccess, where the stats and the image are part of the same structure, and the client is guaranteed to get consistent updates. If you are exporting into a different protocol anyway, the difference shouldn't be that much. In terms of being future-proof, it would be a big step forward.
Cheers, ~Ralph
- Replies:
- Re: areaDetector synchronization question Shen, Guobao via Tech-talk
- Re: areaDetector synchronization question Mark Rivers via Tech-talk
- References:
- areaDetector synchronization question Jörn Dreyer via Tech-talk
- Navigate by Date:
- Prev:
areaDetector synchronization question Jörn Dreyer via Tech-talk
- Next:
Re: areaDetector synchronization question Shen, Guobao via Tech-talk
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
<2022>
2023
2024
- Navigate by Thread:
- Prev:
areaDetector synchronization question Jörn Dreyer via Tech-talk
- Next:
Re: areaDetector synchronization question Shen, Guobao via Tech-talk
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
<2022>
2023
2024
|
ANJ, 14 Sep 2022 |
·
Home
·
News
·
About
·
Base
·
Modules
·
Extensions
·
Distributions
·
Download
·
·
Search
·
EPICS V4
·
IRMIS
·
Talk
·
Bugs
·
Documents
·
Links
·
Licensing
·
|