1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  <20242025  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  <20242025 
<== Date ==> <== Thread ==>

Subject: Re: Retrieve motor-record data from archiver appliance
From: Heinz Junkes via Tech-talk <tech-talk at aps.anl.gov>
To: "Hu, Yong" <yhu at bnl.gov>
Cc: EPICS Tech Talk <tech-talk at aps.anl.gov>
Date: Sun, 30 Jun 2024 15:36:27 +0200
Hi Yong,
Thank you for your e-mail.
When I search for FHIFEL:M11T* it looks like this:

PNG image


And the fields are only displayed in the detail view:


PNG image


We are probably running a very old version:
EPICS Archiver Appliance Version 0.0.1_SNAPSHOT_09-October-2018T15-49-47

But exact same behavior/dislay with  EPICS Archiver Appliance Version d3dd9cc-2022-08-08-aav-fel_SNAPSHOT_28-August-2023T20-42-51

Thanks for the information,
Heinz

P.S.: When I make such a call, the fields data is displayed in the json structure:
http://aa1.fhi-berlin.mpg.de:17668/retrieval/data/getData.json?pv=FHIFEL:M11T&from=2024-06-27T12:59:46.400Z&to=2024-06-27T13:59:46.400Z


> On 29. Jun 2024, at 15:04, Hu, Yong <yhu at bnl.gov> wrote:
> 
> I checked our Archiver Appliance and I can confirm all motor fields, including RBV,  are being archived as expected.
> <image001.png>
> 
> Can you type “FHIFEL:M11T*” (DO NOT forget the magic symbol *) and then click “Check Status” to verify all motor fields are really being archived? Also your version of Archiver Appliance?
> 
> Cheers,
> Yong
> 
> 
> On 6/26/24, 4:47 PM, "Tech-talk" <tech-talk-bounces at aps.anl.gov> wrote:
> Hi,
> We store motor records in the Archiver Appliance.
>   Extra info - RTYP: motor
> Archive Fields DISP,VMAX,UEIP,DMOV,SPMG,RCNT,OMSL,LVIO,ACCL,HVEL,RHLS,FOF,DVAL,SBAK,TWF,URIP,DHLM,STOP,DIFF,RBV,DLLM,UREV,VOF,TWR,RTRY,TWV,RRBV,DISA,SMAX,MSTA,MRES,ERES,SYNC,BDST,TDIR,BACC,HOMF,DRBV,SET,JOGF,NTM,HLM,RRES,RVAL,LLM,RVEL,HOMR,HLS,OFF,FRAC,DLY,JVEL,JOGR,LLS,RDBD,S,CDIR,MISS,VELO,BVEL,ATHM,LOPR,RLLS,SBAS,FOFF,HOPR,RDIF,DIR,SREV,VBAS,JAR,NTMF,REP,MOVN
> Channel Name FHIFEL:M11T
>  Unfortunately, I am not able to read the values of the fields such as DRBV and RBV from the Archiver Appliance. I only ever get the VAL value.
>  What do I have to do?
>  Danke Heinz


Attachment: smime.p7s
Description: S/MIME cryptographic signature


Replies:
Re: Retrieve motor-record data from archiver appliance Timo Korhonen via Tech-talk
References:
Retrieve motor-record data from archiver appliance Heinz Junkes via Tech-talk
Re: Retrieve motor-record data from archiver appliance Hu, Yong via Tech-talk

Navigate by Date:
Prev: Re: Retrieve motor-record data from archiver appliance Hu, Yong via Tech-talk
Next: EPICS 7.0.8.1 Released Johnson, Andrew N. via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  <20242025 
Navigate by Thread:
Prev: Re: Retrieve motor-record data from archiver appliance Hu, Yong via Tech-talk
Next: Re: Retrieve motor-record data from archiver appliance Timo Korhonen via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  <20242025 
ANJ, 11 Sep 2024 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions ·
· Download · Search · IRMIS · Talk · Documents · Links · Licensing ·