1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  <2025 Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  <2025
<== Date ==> <== Thread ==>

Subject: Re: Phytron support for EPICS motor (pull request #8)
From: "Peterson, Kevin M. via Tech-talk" <tech-talk at aps.anl.gov>
To: "tech-talk at aps.anl.gov" <tech-talk at aps.anl.gov>, Lutz Rossa <rossa at helmholtz-berlin.de>
Date: Wed, 22 Jan 2025 20:41:31 +0000
Thanks for the pull request.  I added a comment to the PR discussion.  My only concern is related to the database that includes the motor record.

Kevin

________________________________________
From: Tech-talk on behalf of Lutz Rossa via Tech-talk
Sent: Saturday, January 18, 2025 6:30 AM
To: tech-talk at aps.anl.gov
Subject: Phytron support for EPICS motor (pull request #8)


Hi tech-talk people,

I worked on the Phytron support for EPICS motor, that should also
support the smaller Phytron MCC-1/MCC-2 controllers, which fits
better for single/dual axis applications. These controllers come
also with analog input(s) and digital I/O.

It was matter of my heart to support analog and digital I/O of the
phyMOTION controller. Bernhard Kuner from HZB does not want to
continue his work (issue #5), so I tried to implement these ideas
for both controller types.

For those, who have a Phytron controller, please look at
<https://urldefense.us/v3/__https://github.com/epics-motor/motorPhytron/pull/8__;!!G_uCfscf7eWS!YuyF5kVaR0Zf_x0tv4GdLRZDwGZRxuLlW7TrE2Mmsckcw8NEA7aeJJC5uKT0RASyYRQDMuvEmluCKUhAqJpbZjk$ >
and give comments for this change.

Best regards,
Lutz Rossa
-- 
________________________________
Helmholtz-Zentrum Berlin für Materialien und Energie GmbH
Mitglied der Hermann von Helmholtz-Gemeinschaft Deutscher 
Forschungszentren e.V.

Aufsichtsrat: Vorsitzender Dr. Volkmar Dietz, stv. Vorsitzende Dr. Jutta 
Koch-Unterseher
Geschäftsführung: Prof. Dr. Bernd Rech, Thomas Frederking
Sitz Berlin, AG Charlottenburg, 89 HRB 5583

Postadresse: Hahn-Meitner-Platz 1, D-14109 Berlin
https://urldefense.us/v3/__https://www.helmholtz-berlin.de__;!!G_uCfscf7eWS!YuyF5kVaR0Zf_x0tv4GdLRZDwGZRxuLlW7TrE2Mmsckcw8NEA7aeJJC5uKT0RASyYRQDMuvEmluCKUhAon4ad4A$ 



Replies:
Re: Phytron support for EPICS motor (pull request #8) Lutz Rossa via Tech-talk
References:
Phytron support for EPICS motor (pull request #8) Lutz Rossa via Tech-talk

Navigate by Date:
Prev: Re: EPICS INSTALL_LOCATION/FINAL_LOCATION doesn't work? J. Lewis Muir via Tech-talk
Next: Re: Phytron support for EPICS motor (pull request #8) Lutz Rossa via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  <2025
Navigate by Thread:
Prev: Phytron support for EPICS motor (pull request #8) Lutz Rossa via Tech-talk
Next: Re: Phytron support for EPICS motor (pull request #8) Lutz Rossa via Tech-talk
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  <2025
ANJ, 23 Jan 2025 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions ·
· Download · Search · IRMIS · Talk · Documents · Links · Licensing ·