Hello,
I've been trying to connect to my machine by RS232.
I use streamDevice and Asyn Module.
When we send command "*IDN?", we expect to get "THERMO OK" from the
machine.
I try the same connection on TCP/IP. I used serial to ethernet converter
and communicated with the machine. No problem occured. But when I
eliminated the converter and directly connected to the PC on RS232 port, I
got the following error when I send the command.
I guess the problem is about response time. How can I configure the
response time? Or if it is not response time problem, how can I fix it?
ERROR:
"2013/08/19 16:23:15.340949 thermoConn IDN: No reply from device within
1000 ms"
- Replies:
- Re: Response Time Martin L. Smith
- Re: Response Time Eric Norum
- Re: Response Time Pearson, Matthew R.
- RE: Response Time Mark Rivers
- RE: Response Time Emmanuel Mayssat
- Navigate by Date:
- Prev:
Re: CSS: Can not access PVs in python script Kasemir, Kay
- Next:
Re: Response Time Martin L. Smith
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
<2013>
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
Re: CSS: Can not access PVs in python script Kasemir, Kay
- Next:
Re: Response Time Martin L. Smith
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
<2013>
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
|