1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Question about communications based on modbus tcp.
From: lzf neu <[email protected]>
To: "[email protected]" <[email protected]>
Date: Wed, 24 Jan 2018 08:00:30 +0000

Hi,


There are radiation dose monitor devices by using modbus tcp protocol to communicate.

The communications have succeeded to establish by using epics 3.14.12.5, modbusR1-2 combined with asynR4-9 (very old version) many years ago.

Therefore, I want to upgrade to the latest program by using modbusR2-9 combined with asynR4-30 and epics 3.14.12.5.

My settings are the same as the old version of modbusR1-2 in start.cmd file:


drvAsynIPPortConfigure("Koyo3R",  "192.168.1.241:502",0,1,1)
modbusInterposeConfig("Koyo3R",  2,0,2000)
drvModbusAsynConfigure("RD3R",   "Koyo3R",  3, 0, 95, 0, 1160, "rpDevice") # modbusR1-2 version


I noticed that there was a little difference of parameter settings in the command drvModbusAsynConfigure of new version (modbusR2-9). The manual says :"For TCP the slave address is used for the "unit identifier", the last field in the MBAP header.", and the last field in the MBAP header, as i know,  is the slave address (ranging from 1 to 247).   So, i randomly set:


drvModbusAsynConfigure("RD3R",   "Koyo3R",  111, 3, 0, 95, 0, 1160, "rpDevice")  # modbusR2-9 version, I randomly set 111


or:


drvModbusAsynConfigure("RD3R",   "Koyo3R",  0xFF, 3, 0, 95, 0, 1160, "rpDevice")  # use 0xFF to disable the parameter


however, I cannot establish  the communications by using the new version of modbus and I have no idea how to do.

The error messages are as follows:


epics> 2018/01/24 15:19:26.062 drvModbusAsyn::doModbusIO port RD3R is disconnected
2018/01/24 15:19:30.069 drvModbusAsyn::doModbusIO port RD3R error calling writeRead, error=192.168.1.241:502 timeout: Resource temporarily unavailable, nwrite=6/6, nread=0
2018/01/24 15:19:31.229 drvModbusAsyn::doModbusIO port RD3R has I/O error
2018/01/24 15:19:35.234 drvModbusAsyn::doModbusIO port RD3R error calling writeRead, error=192.168.1.241:502 timeout: Resource temporarily unavailable, nwrite=6/6, nread=0


Any help will be appreciated,  and thanks in advance !


Zhefu






Replies:
Re: Question about communications based on modbus tcp. Mark Rivers

Navigate by Date:
Prev: Re: asyn IP server port driver with streamDevice Mark Rivers
Next: Driver support of VMM ControlNet interface module (5136-CN-VME) 李刚
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: RE: asyn IP server port driver with streamDevice Mark Rivers
Next: Re: Question about communications based on modbus tcp. Mark Rivers
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  2015  2016  2017  <20182019  2020  2021  2022  2023  2024 
ANJ, 26 Jan 2018 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·