For 'dumb mode' I would like the motor record to always send the commands that the user requests and only send those commands.
You aren't required to use the motor record to communicate with model 3
asyn motor drivers. It is possible to use generic EPICS records with
asyn device support to access the various asyn motor parameters, which
would effectively be a 'dumb mode'.