>>> On 4/2/2003 at 15:06:01 CST, Tim Mooney wrote:
> My point is that you can easily distinguish between value monitors and
> archive monitors, so that someone with access to the monitor-control
> field(s) could specify post-every-time for DBE_VALUE clients, and
> post-only-on-change for DBE_LOG clients. People already know about the
> field names MDEL and ADEL for numeric records -- where '-1' means "post
> every time".
I forgot about '-1'. We could use '-1' in that standard sense, and '>=0'
gives the original behavior. Then the only potential confusion is that
positive values of MDEL/ADEL don't mean anything special.
----
Brian McAllister Controls Programmer/Beam Physicist
[email protected] MIT-Bates Linear Accelerator
(617) 253-9537 Middleton, MA