Hi everyone,
I set up a 2-D scan as
follows:
scan1 record: Drive is X motor VAL
field, trigger is scanH.EXSC field. I set its detectors to be ADC.VAL, DAC.VAL
and so on.
scanH record: No positions. Detector
trigger is the field for starting MCA. The detector is mca.VAL which is
the array .
Now, I want to save the ADC.VAL,
DAC.VAL and mca.VAL at the same time. But I can't get it. I find the data of ADC
is later than the data of mca evenif I set scan1.DDLY as 0. So please tell
me how to gain the float data and the array data at the same time.
Thank you!
Best wishes.
Yan Fen
=================================== Yan Fen Shanghai Synchrotron
Radiation Facility Shanghai Institute of Applied Physics Chinese Academy
of Sciences Zhangheng Rd 239,Pudong Dist., Shanghai
201204 China Tel:+86-21-33933191 ===================================
|
- Replies:
- Re: How to get array and float at the same time by sscan Tim Mooney
- Navigate by Date:
- Prev:
How to get array and float at the same time by sscan 闫芬
- Next:
Re: How to get array and float at the same time by sscan Tim Mooney
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
<2009>
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
RE: How to get array and float at the same time by sscan Mark Rivers
- Next:
Re: How to get array and float at the same time by sscan Tim Mooney
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
<2009>
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
|
ANJ, 31 Jan 2014 |
·
Home
·
News
·
About
·
Base
·
Modules
·
Extensions
·
Distributions
·
Download
·
·
Search
·
EPICS V4
·
IRMIS
·
Talk
·
Bugs
·
Documents
·
Links
·
Licensing
·
|