1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: Using Motor Record with READBACK Deadband and number of Retries.
From: Ron Sluiter <[email protected]>
To: "Ernest L. Williams Jr." <[email protected]>
Cc: EPICS <[email protected]>
Date: Fri, 16 Jul 2010 09:11:28 -0500
Hello Ernest,

There is a feedback data flow diagram here on page #17 that may clarify how the motor record feedback works.

Ron

Ernest L. Williams Jr. wrote:
Hi,

We are currently using "Motor Record Version 5.9"
on some of our stepper motor applications.

We would like to use the motor software with USE READBACK enabled.
We are connecting our calibrated LVDT to the READBACK link.

What has been your experience in using this feature of the Motor Record?


When using READBACK inlink for Motor position sensing:
(1) Selecting YES/NO does not update the motor record properly.
Should the software actually copy the contents of MOTOR.VAL to MOTOR.RBV
If READBACK is toggled back to "NO"

If the READBACK is set to "YES" then "MOTOR.RDBL", should be copied to MOTOR.RBV ?





Thanks in Advance,
Ernest
SLAC





Replies:
Re: Using Motor Record with READBACK Deadband and number of Retries. Ernest L. Williams Jr.
References:
Using Motor Record with READBACK Deadband and number of Retries. Ernest L. Williams Jr.

Navigate by Date:
Prev: RE: areaDetector problem John Dobbins
Next: Re: Using Motor Record with READBACK Deadband and number of Retries. Ernest L. Williams Jr.
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: Re: Using Motor Record with READBACK Deadband and number of Retries. Ernest L. Williams
Next: Re: Using Motor Record with READBACK Deadband and number of Retries. Ernest L. Williams Jr.
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  <20102011  2012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 02 Sep 2010 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·