1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019 
<== Date ==> <== Thread ==>

Subject: Re: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232?
From: Wesley Moore <wmoore@jlab.org>
To: Jay Steele <jsteele@xradia.com>
Cc: "tech-talk@aps.anl.gov" <tech-talk@aps.anl.gov>
Date: Mon, 16 May 2011 07:45:43 -0400
Jay Steele wrote:
Hi EPICS folks,
Has anybody developed a EPICS module to communicate with the OMRON PLC SYSMAC CJIM CPU12-ETN using Ethernet TCP/IP sockets? I'm prepared to develop such a module using the asyn framework, but wanted to check if anybody has done this already. We use the OMRON PLC for cryogenics and vacuum control for our bionanoprobe X-ray fluorescence instruments. I see references to Omron PLCs on the EPICS website from Paul Hamadyk and Mauro Giacchini, but only for RS-232 communications. Has anybody developed a EPICS module for RS-232 communications with CryoCon temperature controllers? Again I'm prepared to develop such a module using the asyn framework, but wanted to check if anybody has done this already. Thanks,
Jay Steele
Xradia Corporation
Jay,

I've got a driver that I've been using for years with no problems. Uses the FINS protocol over TCP/IP (not using asyn). It originally came from KEK, but I did some modifications to it since then.
Wesley
FEL, JLab
begin:vcard
fn:Wesley Moore
n:Moore;Wesley
org:Thomas Jefferson National Accelerator Facility;Free Electron Laser
adr:Suite 19, MS 18;;12000 Jefferson Avenue;Newport News;VA;23606;USA
email;internet:wmoore@jlab.org
title:FEL Computer Scientist
tel;work:(757) 269-6033
tel;fax:(757) 269-6384
tel;pager:(757) 584-6033
url:http://www.jlab.org/FEL/
version:2.1
end:vcard


References:
EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? Jay Steele

Navigate by Date:
Prev: Announce: seq-2.0.14 Benjamin Franksen
Next: RE: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? emma.shepherd
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019 
Navigate by Thread:
Prev: RE: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? Jay Steele
Next: Announce: seq-2.0.14 Benjamin Franksen
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019 
ANJ, 18 Nov 2013 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·