1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: Re: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232?
From: Wesley Moore <[email protected]>
To: Jay Steele <[email protected]>
Cc: "[email protected]" <[email protected]>
Date: Mon, 16 May 2011 07:45:43 -0400
Jay Steele wrote:
Hi EPICS folks,
Has anybody developed a EPICS module to communicate with the OMRON PLC SYSMAC CJIM CPU12-ETN using Ethernet TCP/IP sockets? I'm prepared to develop such a module using the asyn framework, but wanted to check if anybody has done this already. We use the OMRON PLC for cryogenics and vacuum control for our bionanoprobe X-ray fluorescence instruments. I see references to Omron PLCs on the EPICS website from Paul Hamadyk and Mauro Giacchini, but only for RS-232 communications. Has anybody developed a EPICS module for RS-232 communications with CryoCon temperature controllers? Again I'm prepared to develop such a module using the asyn framework, but wanted to check if anybody has done this already. Thanks,
Jay Steele
Xradia Corporation
Jay,

I've got a driver that I've been using for years with no problems. Uses the FINS protocol over TCP/IP (not using asyn). It originally came from KEK, but I did some modifications to it since then.
Wesley
FEL, JLab
begin:vcard
fn:Wesley Moore
n:Moore;Wesley
org:Thomas Jefferson National Accelerator Facility;Free Electron Laser
adr:Suite 19, MS 18;;12000 Jefferson Avenue;Newport News;VA;23606;USA
email;internet:[email protected]
title:FEL Computer Scientist
tel;work:(757) 269-6033
tel;fax:(757) 269-6384
tel;pager:(757) 584-6033
url:http://www.jlab.org/FEL/
version:2.1
end:vcard


References:
EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? Jay Steele

Navigate by Date:
Prev: Announce: seq-2.0.14 Benjamin Franksen
Next: RE: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? emma.shepherd
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: RE: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? Jay Steele
Next: Announce: seq-2.0.14 Benjamin Franksen
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 18 Nov 2013 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·