Hi Emma,
Yes - I'll test out your streamDevice code if you want to share it.
Thanks,
Jay Steele
Xradia Corporation
________________________________________
From: [email protected] [[email protected]]
Sent: Monday, May 16, 2011 5:26 AM
To: Jay Steele; [email protected]; [email protected]
Cc: Claus Flachenecker
Subject: RE: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232?
Hi Jay,
We've also got some streamDevice support for the Cryocon M32 and M14 controllers - if these are the models you are interested in I can send you the code.
Cheers,
Emma
-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Jay Steele
Sent: 13 May 2011 21:42
To: Rees, Nick (DLSLtd,RAL,DIA); [email protected]
Cc: Claus Flachenecker
Subject: RE: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232?
Hi Nick,
Thanks a lot.
Cheers,
Jay Steele
Xradia Corporation
________________________________________
From: [email protected] [[email protected]]
Sent: Friday, May 13, 2011 12:52 PM
To: Jay Steele; [email protected]
Subject: Re: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232?
Hi Jay,
We now use Ethernet for communication with our Omron PLC's, and will do so for all future developments. I will get Paul Hamadyk to send you the details next week.
Cheers,
Nick Rees
Principal Software Engineer Phone: +44 (0)1235-778430
Diamond Light Source Fax: +44 (0)1235-446713
----- Reply message -----
From: "Jay Steele" <[email protected]>
Date: Fri, May 13, 2011 20:15
Subject: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232?
To: "[email protected]" <[email protected]>
Hi EPICS folks,
Has anybody developed a EPICS module to communicate with the OMRON PLC SYSMAC CJIM CPU12-ETN using Ethernet TCP/IP sockets? I'm prepared to develop such a module using the asyn framework, but wanted to check if anybody has done this already. We use the OMRON PLC for cryogenics and vacuum control for our bionanoprobe X-ray fluorescence instruments. I see references to Omron PLCs on the EPICS website from Paul Hamadyk and Mauro Giacchini, but only for RS-232 communications.
Has anybody developed a EPICS module for RS-232 communications with CryoCon temperature controllers? Again I'm prepared to develop such a module using the asyn framework, but wanted to check if anybody has done this already.
Thanks,
Jay Steele
Xradia Corporation
________________________________
The information in this email, including any attachments, is confidential and intended only for the recipient(s) listed. Any use of this email for any other purpose is prohibited. If you have received this email in error, please notify me immediately by reply email, delete this email, and do not disclose its contents to anyone.
--
This e-mail and any attachments may contain confidential, copyright and or privileged material, and are for the use of the intended addressee only. If you are not the intended addressee or an authorised recipient of the addressee please notify us of receipt by returning the e-mail and do not use, copy, retain, distribute or disclose the information in or attached to the e-mail.
Any opinions expressed within this e-mail are those of the individual and not necessarily of Diamond Light Source Ltd.
Diamond Light Source Ltd. cannot guarantee that this e-mail or any attachments are free from viruses and we cannot accept liability for any damage which you may sustain as a result of software viruses which may be transmitted in or with the message.
Diamond Light Source Limited (company no. 4375679). Registered in England and Wales with its registered office at Diamond House, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom
The information in this email, including any attachments, is confidential and intended only for the recipient(s) listed. Any use of this email for any other purpose is prohibited. If you have received this email in error, please notify me immediately by reply email, delete this email, and do not disclose its contents to anyone.
--
This e-mail and any attachments may contain confidential, copyright and or privileged material, and are for the use of the intended addressee only. If you are not the intended addressee or an authorised recipient of the addressee please notify us of receipt by returning the e-mail and do not use, copy, retain, distribute or disclose the information in or attached to the e-mail.
Any opinions expressed within this e-mail are those of the individual and not necessarily of Diamond Light Source Ltd.
Diamond Light Source Ltd. cannot guarantee that this e-mail or any attachments are free from viruses and we cannot accept liability for any damage which you may sustain as a result of software viruses which may be transmitted in or with the message.
Diamond Light Source Limited (company no. 4375679). Registered in England and Wales with its registered office at Diamond House, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom
The information in this email, including any attachments, is confidential and intended only for the recipient(s) listed. Any use of this email for any other purpose is prohibited. If you have received this email in error, please notify me immediately by reply email, delete this email, and do not disclose its contents to anyone.
- References:
- EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? Jay Steele
- Re: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? nick.rees
- RE: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? Jay Steele
- RE: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? emma.shepherd
- Navigate by Date:
- Prev:
RE: EPICS support for Delta Tau UMAC system Zhan Zhang
- Next:
Channel Access not connecting Bruce Hill
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
<2011>
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
- Navigate by Thread:
- Prev:
RE: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? emma.shepherd
- Next:
Re: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? Wesley Moore
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
<2011>
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
|