1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
<== Date ==> <== Thread ==>

Subject: RE: EPICS support for Delta Tau UMAC system
From: "Zhan Zhang" <[email protected]>
To: <[email protected]>
Date: Mon, 16 May 2011 13:26:55 -0500
Thanks to Daron, Mark & Matthew!  
Now I know where to start.  I had been to the
page--http://www.gmca.anl.gov/TPMAC2/index.html a couple of times before but
didn't know that's what I need since I had no clue.  I will play with it a
bit now.  
Thanks again!

Zhan

---------------------------------
Zhan Zhang, Ph. D.
Argonne National Laboratory
X-ray Science Division, 438-D005
9700 S. Cass Ave.
Argonne, IL 60439
Tel : 630-252-0863
Email: [email protected]

-----Original Message-----
From: [email protected] [mailto:[email protected]] 
Sent: Monday, May 16, 2011 12:50 PM
To: [email protected]; [email protected]
Subject: RE: EPICS support for Delta Tau UMAC system

Hi Zhan,

The tpmac support module has support for ethernet PMACs. There is an Asyn
interpose layer that deals with the additional protocol that the ethernet
PMACs need.

In your IOC startup file, you'll need something like this:

#Asyn PORT name, #IP address and IP port 
pmacAsynIPConfigure("pmacLV", "172.23.243.156:1025") 

#Asyn PORT name, #Asyn ADDR, #Card ID, #Number of axes
pmacAsynMotorCreate("pmacLV", 0, 0, 8) 

#Asyn PORT name for motor record, #Asyn motor driver name, #Card ID, #Number
of axes+1 
drvAsynMotorConfigure("PMAC1", "pmacAsynMotor", 0, 9)

Hope this helps.

Cheers,
Matthew

> -----Original Message-----
> From: [email protected] [mailto:tech-talk-
> [email protected]] On Behalf Of Zhan Zhang
> Sent: 16 May 2011 17:59
> To: [email protected]
> Subject: EPICS support for Delta Tau UMAC system
> 
> Hi folks,
> 	I wonder if anyone has developed EPICS support for the Delta Tau
> UMAC system.  This is a 3-U rack-mount system with power supply,
> drivers,
> controllers, and communication board (a turbo PMAC2 board), which
> communicates with the host PC via USB or Ethernet (or serial).  My
> communication/CPU board has a SN # 3X0-603766 and unfortunately, I
> could not
> find the product on the Delta Tau webpage.
> 	A simple search on this list suggests there were enough work done
> on
> the PMAC-VME controller.  But I don't see any related to the UMAC
> system I
> have.  Anyone has any information?  Thanks a lot!
> 
> Zhan
> 
> ---------------------------------
> Zhan Zhang, Ph. D.
> Argonne National Laboratory
> X-ray Science Division, 438-D005
> 9700 S. Cass Ave.
> Argonne, IL 60439
> Tel : 630-252-0863
> Email: [email protected]


-- 
This e-mail and any attachments may contain confidential, copyright and or
privileged material, and are for the use of the intended addressee only. If
you are not the intended addressee or an authorised recipient of the
addressee please notify us of receipt by returning the e-mail and do not
use, copy, retain, distribute or disclose the information in or attached to
the e-mail.
Any opinions expressed within this e-mail are those of the individual and
not necessarily of Diamond Light Source Ltd. 
Diamond Light Source Ltd. cannot guarantee that this e-mail or any
attachments are free from viruses and we cannot accept liability for any
damage which you may sustain as a result of software viruses which may be
transmitted in or with the message.
Diamond Light Source Limited (company no. 4375679). Registered in England
and Wales with its registered office at Diamond House, Harwell Science and
Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom
 





References:
Handling failures in st.cmd Zelazny, Michael Stanley
Re: Handling failures in st.cmd Ernest L. Williams Jr.
Re: Handling failures in st.cmd Benjamin Franksen
EPICS support for Delta Tau UMAC system Zhan Zhang
RE: EPICS support for Delta Tau UMAC system matthew.pearson

Navigate by Date:
Prev: RE: EPICS support for Delta Tau UMAC system matthew.pearson
Next: RE: EPICS support for OMRON PLC SYSMAC CJIM CPU12-ETN Ethernet communications? CryoCon RS-232? Jay Steele
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
Navigate by Thread:
Prev: RE: EPICS support for Delta Tau UMAC system matthew.pearson
Next: Re: EPICS support for Delta Tau UMAC system Kevin Peterson
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  <20112012  2013  2014  2015  2016  2017  2018  2019  2020  2021  2022  2023  2024 
ANJ, 18 Nov 2013 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·