1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  <20142015  2016  2017  2018  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  <20142015  2016  2017  2018 
<== Date ==> <== Thread ==>

Subject: Re: IOC server on windows or access a PV
From: zunbeltz <zunbeltz.izaola@essbilbao.org>
To: xiaoqiang.wang@psi.ch
Cc: tech-talk@aps.anl.gov
Date: Fri, 03 Oct 2014 09:31:08 +0200
Dear Xiaoquiang,

Thanks for the information.
What is important to me is also to have a proper timestamp for the PVs and I an not very confident on the windows machine. If I install a portable channel access server, the timestamps of the PVs I serve there will be taken from the windows machine; am I right? If I have the server in other computer the timestamp of the uploaded PV will be given by that other server, not the "caput" operation I run in the windows; isn't it?

Best regards,

Zunbeltz


og., 2014.eko urrren 02a 22:13(e)an, Xiaoqiang Wang igorleak idatzi zuen:
Hi,

There is a 3rd choice: create the PV in portable channel access server.

If your calculation code can be invoked with Python, be it a C extension or separate program (using subprocess module).
This can be easy to write using PCASpy[1] extension.

Best
Xiaoqiang

[1] https://pypi.python.org/pypi/pcaspy


On 02 Oct 2014, at 21:48, zunbeltz <zunbeltz.izaola@essbilbao.org> wrote:

Dear all,

We need to pass some values, calculated from photographs, to the EPICS network from a windows machine.
Is it easy to install an IOC server in a windows machine?
If not, our idea is to create the PVs in an already running IOC server (on linux), and use caput tool (from the EPICS Extensions http://aps.anl.gov/epics/distributions/win32/index.php) to update the values.
Is it possible to create an  PV that is not associated with any hardware in a IOC server? Is it enough to add a record in the ioc.db file?

Thanks in advance for your help.

Zunbeltz
--
Dr. Zunbeltz Izaola
Accelerator Physics Group
ESS-Bilbao


--
Dr. Zunbeltz Izaola
Accelerator Physics Group
ESS-Bilbao


Replies:
Re: IOC server on windows or access a PV Xiaoqiang Wang
References:
IOC server on windows or access a PV zunbeltz
Re: IOC server on windows or access a PV Xiaoqiang Wang

Navigate by Date:
Prev: Re: IOC server on windows or access a PV zunbeltz
Next: Re: IOC server on windows or access a PV zunbeltz
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  <20142015  2016  2017  2018 
Navigate by Thread:
Prev: Re: IOC server on windows or access a PV Xiaoqiang Wang
Next: Re: IOC server on windows or access a PV Xiaoqiang Wang
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  <20142015  2016  2017  2018 
ANJ, 17 Dec 2015 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·