1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  <20152016  2017  2018  2019  2020  Index 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  <20152016  2017  2018  2019  2020 
<== Date ==> <== Thread ==>

Subject: Re: Serial port COM10: not work?
From: Eric Norum <eric@norum.ca>
To: Mark Rivers <rivers@cars.uchicago.edu>
Cc: "EPICS Tech-Talk \(tech-talk@aps.anl.gov\)" <tech-talk@aps.anl.gov>
Date: Wed, 30 Sep 2015 11:18:41 -0700
On Sep 30, 2015, at 10:31 AM, Mark Rivers <rivers@cars.uchicago.edu> wrote:

The code in question is in the Windows-specific driver file (drvAsynSerialPortWin32.c), so it is already Windows-specific.  We are not adding OS-specific code to a generic driver.
Oops — I forgot that windows didn’t use the Posix termios code.
 
I don’t like users having to put 6 backslash characters into the device name, where everywhere else in Windows they just say COM10.
 
I agree with Peter’s suggestion that we don’t need a special case for COM1-COM9. 
 
I propose the following:
 
-          If the device name passed to drvAsynSerialPortConfigure starts with  ‘\’  then assume the user has used a device name, and use it directly.
-          If the device name does not begin with ‘\’ then prepend “\\.\”.
That sounds ideal.
-- 
Eric Norum
eric@norum.ca





Replies:
Re: Serial port COM10: not work? Torsten Bögershausen
References:
Serial port COM10: not work? Heesterman, Peter J
Re: Serial port COM10: not work? Jack
RE: Serial port COM10: not work? Mark Rivers
Re: Serial port COM10: not work? Eric Norum
RE: Serial port COM10: not work? Mark Rivers

Navigate by Date:
Prev: RE: Serial port COM10: not work? Mark Rivers
Next: RE: New sequencer releases Mark Rivers
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  <20152016  2017  2018  2019  2020 
Navigate by Thread:
Prev: RE: Serial port COM10: not work? Mark Rivers
Next: Re: Serial port COM10: not work? Torsten Bögershausen
Index: 1994  1995  1996  1997  1998  1999  2000  2001  2002  2003  2004  2005  2006  2007  2008  2009  2010  2011  2012  2013  2014  <20152016  2017  2018  2019  2020 
ANJ, 16 Dec 2015 Valid HTML 4.01! · Home · News · About · Base · Modules · Extensions · Distributions · Download ·
· Search · EPICS V4 · IRMIS · Talk · Bugs · Documents · Links · Licensing ·