and eliminate white space in the .CALC expression
On 11/1/2022 11:46 AM, Arnold, Ned D. via Tech-talk wrote:
> Try to simplify your expression,
and use spare INP fields to hold constants ... C>=1.75&&C => C>=F&&C (INPF=1.75)
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
*From:* Tech-talk <[email protected]> on behalf of Kasemir, Kay via Tech-talk <[email protected]>
*Sent:* Tuesday, November 1, 2022 11:13 AM
*To:* [email protected] <[email protected]>; Meddage, Varuna <[email protected]>
*Subject:* Re: calc type record question
The length of the CALC field is limited something around 80 characters.
Try to simplify your expression, for example by removing some parentheses that are good for readability but not strictly necessary.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
*From:* Tech-talk <[email protected]> on behalf of Meddage, Varuna via Tech-talk <[email protected]>
*Sent:* Tuesday, November 1, 2022 11:08 AM
*To:* [email protected] <[email protected]>
*Subject:* [EXTERNAL] calc type record question
Hi,
I have following "calc" type record in one of my .db files.
===============================================================
record(calc,"$(detector)_wib$(crate)0$(wib)/calc")
{
field(SCAN,"5 second")
field(CALC,"((A>=4.6&&A<=5.2)&&(B>=4.6&&B<=5.2)&&(C>=1.75&&C<=1.80)&&(D>=3.2&&D<=3.4)&&(E>=0.7&&E<=2.0))?1:0")
field(INPA,"$(detector)_wib$(crate)0$(wib)/vcc")
field(INPB,"$(detector)_wib$(crate)0$(wib)/v1")
field(INPC,"$(detector)_wib$(crate)0$(wib)/v2")
field(INPD,"$(detector)_wib$(crate)0$(wib)/v3")
field(INPE,"$(detector)_wib$(crate)0$(wib)/v4")
field(DESC,"")
field(HIHI,"")
field(HIGH,"")
field(LOW,"")
field(LOLO,"")
field(MDEL,"-1")
field(ADEL,"-1")
field(OOPT,"Every Time")
field(PREC,"6")
}
===============================================================
When I run the EPICS, then I get an error message saying "String is too long" complaining about the expression, I inserted inside the "CALC" field in this record. But when I reduced the number of input PVs of this record from 5 to 4 and rewrite the expression inside "CALC" field, then there is no error.
Is there maximum number of input PVs, that I can use inside a "calc" type record ?
Any help to understand this issue is highly appreciated.
Thanks
Varuna Meddage
--
----------------------------------------------------------
Pete R. Jemian, Ph.D. <[email protected]>
Beam line Controls and Data Acquisition (BC, aka BCDA)
Advanced Photon Source, Argonne National Laboratory
Argonne, IL 60439 630 - 252 - 3189
-----------------------------------------------------------
Education is the one thing for which people
are willing to pay yet not receive.
-----------------------------------------------------------
- References:
- calc type record question Meddage, Varuna via Tech-talk
- Re: calc type record question Kasemir, Kay via Tech-talk
- Re: calc type record question Arnold, Ned D. via Tech-talk
- Navigate by Date:
- Prev:
Re: calc type record question Arnold, Ned D. via Tech-talk
- Next:
RE: calc type record question GAGET Alexis via Tech-talk
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
<2022>
2023
2024
2025
2026
- Navigate by Thread:
- Prev:
Re: calc type record question Arnold, Ned D. via Tech-talk
- Next:
RE: calc type record question GAGET Alexis via Tech-talk
- Index:
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
<2022>
2023
2024
2025
2026
|